  • The U.S. Air Force started using copper-based, lead-free frangible ammunition in the early 2000s to address environmental and health concerns stemming from lead exposure.
  • In a study assessing aerosol emissions at a firing range, instructors reported health issues like respiratory distress, despite measurements showing airborne metals were below occupational limits.
  • The evaluation found that while copper levels in the air were low, there was a significant increase in ultrafine particle concentrations during firing, suggesting that existing exposure guidelines may not adequately protect instructors' health.

Article Abstract

U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = <1 µg/m to 16 µg/m), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459624.2017.1296232DOI Listing

Publication Analysis

Top Keywords

firing
8
lead-free frangible
8
frangible ammunition
8
firing range
8
firing ranges
8
health concerns
8
instructor exposure
8
air sampling
8
air
6
characterization exposure
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!