Evaluation of noise limits to improve image processing in soft X-ray projection microscopy.

J Xray Sci Technol

Graduate School of Advanced Integration Science, Chiba University, Chiba-shi, Chiba, Japan.

Published: March 2017

Soft X-ray microscopy has been developed for high resolution imaging of hydrated biological specimens due to the availability of water window region. In particular, a projection type microscopy has advantages in wide viewing area, easy zooming function and easy extensibility to computed tomography (CT). The blur of projection image due to the Fresnel diffraction of X-rays, which eventually reduces spatial resolution, could be corrected by an iteration procedure, i.e., repetition of Fresnel and inverse Fresnel transformations. However, it was found that the correction is not enough to be effective for all images, especially for images with low contrast. In order to improve the effectiveness of image correction by computer processing, we in this study evaluated the influence of background noise in the iteration procedure through a simulation study. In the study, images of model specimen with known morphology were used as a substitute for the chromosome images, one of the targets of our microscope. Under the condition that artificial noise was distributed on the images randomly, we introduced two different parameters to evaluate noise effects according to each situation where the iteration procedure was not successful, and proposed an upper limit of the noise within which the effective iteration procedure for the chromosome images was possible. The study indicated that applying the new simulation and noise evaluation method was useful for image processing where background noises cannot be ignored compared with specimen images.

Download full-text PDF

Source
http://dx.doi.org/10.3233/XST-16201DOI Listing

Publication Analysis

Top Keywords

iteration procedure
16
image processing
8
soft x-ray
8
chromosome images
8
images
7
noise
5
evaluation noise
4
noise limits
4
limits improve
4
image
4

Similar Publications

The present evaluation aimed to begin development of a survey tool for measuring workplace stressors specific to behavioral health providers in clinical settings for autism and related developmental disabilities: the Burnout Assessment for Developmental Disability Settings (BADDS). BADDS development was guided by Patient-Reported Outcomes Measurement Information System (PROMIS; Cella et al., (Journal of Clinical Epidemiology, 63(11), 1179-1194, 2010) procedures.

View Article and Find Full Text PDF

Background And Aim: The APAGE Position Statements aimed to provide guidance to healthcare practitioners on clinical practices aligned with climate sustainability.

Methods: A taskforce convened by APAGE proposed provisional statements. Twenty-two gastroenterologists from the Asian Pacific region participated in online voting and consensus was assessed through an anonymized and iterative Delphi process.

View Article and Find Full Text PDF

Background: Proton pencil beam scanning (PBS) treatment planning for head and neck (H&N) cancers is a time-consuming and experience-demanding task where a large number of potentially conflicting planning objectives are involved. Deep reinforcement learning (DRL) has recently been introduced to the planning processes of intensity-modulated radiation therapy (IMRT) and brachytherapy for prostate, lung, and cervical cancers. However, existing DRL planning models are built upon the Q-learning framework and rely on weighted linear combinations of clinical metrics for reward calculation.

View Article and Find Full Text PDF

Background: Deep learning image reconstruction (DLIR) algorithms allow strong noise reduction while preserving noise texture, which may potentially improve hypervascular focal liver lesions.

Purpose: To assess the impact of DLIR on image quality (IQ) and detectability of simulated hypervascular hepatocellular carcinoma (HCC) in fast kV-switching dual-energy CT (DECT).

Methods: An anthropomorphic phantom of a standard patient morphology (body mass index of 23 kg m) with customized liver, including mimickers of hypervascular lesions in both late arterial phase (AP) and portal venous phase (PVP) enhancement, was scanned on a DECT.

View Article and Find Full Text PDF

Objective: This study presents the results of a surgical instrument tray optimization process implemented across all surgical specialties within the largest university hospital in Denmark.

Methods: Data was extracted from a comprehensive instrument optimization process including all Operating Rooms at Aarhus University Hospital. Adopting a holistic perspective, the optimization process, involved aligning instrument trays across various surgical specialties.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!