This work presents a Monte Carlo simulation using the last version of MCNP, v. 6.1.1, of a Varian CLinAc emitting a 15MeV photon beam. The main objective of the work is to estimate the photoneutron production and activated products inside the medical linear accelerator head. To that, the Varian LinAc head was modelled in detail using the manufacturer information, and the model was generated with a CAD software and exported as a mesh to be included in the particle transport simulation. The model includes the transport of photoneutrons generated by primary photons and the (n, γ) reactions which can result in activation products. The validation of this study was done using experimental measures. Activation products have been identified by in situ gamma spectroscopy placed at the jaws exit of the LinAc shortly after termination of a high energy photon beam irradiation. Comparison between experimental and simulation results shows good agreement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2016.7592010 | DOI Listing |
J Am Coll Cardiol
December 2024
UCL MRC Unit for Lifelong Health and Ageing, University College London, London, United Kingdom; UCL Institute of Cardiovascular Science, University College London, London, United Kingdom; Centre for Inherited Heart Muscle Conditions, Cardiology Department, Royal Free Hospital, London, United Kingdom. Electronic address:
Background: Aircraft noise is a growing concern for communities living near airports.
Objectives: This study aimed to explore the impact of aircraft noise on heart structure and function.
Methods: Nighttime aircraft noise levels (L) and weighted 24-hour day-evening-night aircraft noise levels (L) were provided by the UK Civil Aviation Authority for 2011.
Psychiatry Clin Psychopharmacol
December 2024
Department of Operating Room, the Fifth Affiliated Hospital of Wenzhou Medical University, Lishui Central Hospital, Lishui, China.
Background: Interventional therapy, currently, has become a major method for the clinical treatment of liver cancer patients. However, interventional therapy can also lead to various toxic side effects, and combined with the impact of the disease itself, liver cancer patients often experience more severe emotional distress. Improving individuals' levels of psychological distress tolerance may reduce sensitivity to negative life events and experiences.
View Article and Find Full Text PDFVaccines (Basel)
December 2024
The Shamir Medical Center (Assaf Harofeh), Rishon LeZion, 4 Icet, Zrifin 7033001, Israel.
In response to the COVID-19 pandemic, Israel prioritized pregnant women for vaccination, recognizing them as a high-risk group. This study aims to explore factors influencing the acceptance of Influenza, Pertussis (T-dap), and COVID-19 vaccines among pregnant women, focusing on attitudes, social norms, perceived control, and risk perceptions. Additionally, the study compares acceptance patterns between traditional vaccines and the newer COVID-19 vaccine.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 03680 Kyiv, Ukraine.
This work presents the development of an amperometric biosensor for detecting aspartate aminotransferase (AST) activity in biological fluids using a platinum disk electrode as the working transducer. Optimal concentrations of substrates (aspartate, α-ketoglutarate) and the coenzyme (pyridoxal phosphate) were determined to ensure efficient biosensor operation. A semi-permeable poly-m-phenylenediamine membrane was applied to enhance selectivity against electroactive interferents.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!