A shearing interference microscope using a Savart prism as the shear plate is proposed for inspecting step-heights. Where the light beam propagates through the Savart prism and microscopic system to illuminate the sample, it then turns back to re-pass through the Savart prism and microscopic system to generate a shearing interference pattern on the camera. Two measurement modes, phase-shifting and phase-scanning, can be utilized to determine the depths of the step-heights on the sample. The first mode, which employs a narrowband source, is based on the five-step phase-shifting algorithm and has a measurement range of a quarter-wavelength. The second mode, which adopts a broadband source, is based on peak-intensity identification technology and has a measurement range up to a few micrometres. This paper is to introduce the configuration and measurement theory of this microscope, perform a setup used to implement it, and present the experimental results from the uses of the setup. The results not only verify the validity but also confirm the high measurement repeatability of the proposed microscope.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jmi.12527DOI Listing

Publication Analysis

Top Keywords

shearing interference
12
savart prism
12
interference microscope
8
prism microscopic
8
microscopic system
8
source based
8
measurement range
8
measurement
5
microscope
4
microscope step-height
4

Similar Publications

Highly Sensitive Linear Triaxial Force Sensor Based on Multimodal Sensing for 3D Pose Reconstruction.

Small Methods

January 2025

National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, 200240, China.

Flexible sensing offers real-time force monitoring, presenting a versatile and effective solution for dexterous manipulation, healthcare, environmental exploration, and perception of physical properties. Nonetheless, a limitation of many existing flexible force sensors stems from their isotropic structure or material properties, preventing them from simultaneously detecting both the direction and magnitude of the applied force. Herein, a high-performance 3D force sensor based on orthogonal multimodal sensing, the cancellation principle, and the strain effect is proposed.

View Article and Find Full Text PDF

Recapitulation of physiologic and pathophysiologic pulsatile CSF flow in purpose-built high-throughput hydrocephalus bioreactors.

Fluids Barriers CNS

December 2024

Department of Chemical Engineering and Materials Science, Wayne State University, 6135 Woodward Avenue, Rm 1413, Detroit, MI, 48202, USA.

Background: Hydrocephalus, an accumulation of cerebrospinal fluid (CSF) in the ventricles of the brain, is often treated via a shunt system to divert the excess CSF to a different compartment; if left untreated, it can lead to serious complications and permanent brain damage. It is estimated that one in every 500 people are born with hydrocephalus. Despite more than 60 years of concerted efforts, shunts still have the highest failure rate of any neurological device requiring follow-up shunt revision surgeries and contributing to the $2 billion cost of hydrocephalus care in the US alone.

View Article and Find Full Text PDF

Recent experiments revealed a new amorphous ice phase, medium-density amorphous ice (MDA), formed by ball-milling ice at 77 K [Rosu-Finsen , Science , 474-478 (2023)]. MDA has density between that of low-density amorphous (LDA) and high-density amorphous (HDA) ices, adding to the complexity of water's phase diagram, known for its glass polyamorphism and two-state thermodynamics. The nature of MDA and its relation to other amorphous ices and liquid water remain unsolved.

View Article and Find Full Text PDF

Ultrasound elastography is a promising new technique in the evaluation of the thyroid nodule. It allows for "virtual palpation" of the nodule, even smaller ones which may not be otherwise palpable clinically. Ultrasound elastography was developed to obtain information on tissue stiffness non-invasively.

View Article and Find Full Text PDF

Dual Gold Nanostructures-Based Stretchable Electrochemiluminescence Sensors for Hydrogen Peroxide Monitoring in Endothelial Mechanotransduction.

ACS Sens

November 2024

Ministry of Education Key Laboratory for the Synthesis and Application of Organic Functional Molecules, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, College of Chemistry and Chemical Engineering, Hubei University, Wuhan 430062, China.

Article Synopsis
  • Hydrogen peroxide (HO) release in blood flow is crucial for vascular health, and it is triggered by mechanical stress on endothelial cells.* -
  • The study introduces a novel stretchable electrochemiluminescence (ECL) sensor made from gold nanostructures that specifically detects HO levels, overcoming interference from cell secretions.* -
  • By using human umbilical vein endothelial cells, the sensor can monitor HO release in real time during stretching, showcasing its potential for biomedical applications and health monitoring.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!