One of the important factors in determining the success of joint replacement is the wear performance of polyethylene. Although highly crosslinked polyethylene (CLPE) is presently used, it is still not adequate. We have developed a surface modification technology using poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) in an attempt to improve wear performance. In this study, we evaluated the wear and creep deformation resistances of 3-mm and 6-mm thick PMPC-grafted CLPE disks, set on a metal back-plate, with and without a sham screw hole. The gravimetric wear and volumetric change of the disks were examined using a multidirectional pin-on-disk tester. PMPC grafting decreased the gravimetric wear of CLPE regardless of the presence of a screw hole, and did not affect the volumetric change. The volumetric change in the bearing and backside surfaces of the 3-mm thick disk with a screw hole was much larger than that of those without a screw hole or those of the 6-mm thick disk, which was caused by creep deformation. PMPC grafting on the bearing surface can be a material engineering approach to reduce the wear without changing the creep deformation resistance, and is a promising surface modification technology that can be used to increase the longevity of various artificial joints. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 610-618, 2018.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jbm.b.33837 | DOI Listing |
J Hand Surg Glob Online
November 2024
The Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, MD.
Purpose: Osteoporotic patients are at risk of peri-implant fractures after distal radius fixation. A unicortical screw in the proximal hole of the plate can theoretically decrease stress riser formation by eliminating the hole in the far bone cortex. This construct has been proposed in orthopedic literature to prevent peri-implant fractures but has not been tested in an osteoporotic distal radius model.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
Department of Furniture Design, Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, 60-637 Poznań, Poland.
Many factors affect screw withdrawal resistance (SWR), including screw size, embedment depth, the pre-drilled hole's diameter, dimensional accuracy, and the furniture pieces' material properties being joined. While prior research has extensively examined the influence of these factors, this study aimed to explore a neglected factor: how drill bit wear impacts pilot hole quality and subsequent SWR. The experimental setup included pinewood samples with pre-drilled 5 mm diameter blind pilot holes with a depth of 45 mm.
View Article and Find Full Text PDFUlus Travma Acil Cerrahi Derg
January 2024
Department of Orthopedics and Traumatology, Mersin VM Medical Park Hospital, Mersin-Türkiye.
Background: The anatomy of the proximal tibia presents treatment challenges, and there is currently no widely accepted surgical fixation method for fractures in this region. The aim of this study is to evaluate the efficacy, benefits, and differences between intramedullary nailing (IMN) with a 4-hole Limited Contact Dynamic Compression Plate (LC-DCP) combination and IMN with an 8-hole LC-DCP combination in unstable fractures of the proximal metaphyseal region of the tibia.
Methods: An oblique fracture was created in the metaphyseal region, forming a 30-degree angle in the sagittal plane in three tibial models.
Cureus
December 2024
Trauma and Orthopaedics, Guy's and St Thomas' Trust, London, GBR.
Background and aim Synthetic composite bone models (reinforced solid foam) have become the standardised material used in practical orthopaedic education. However, with discussions regarding whether composite foam truly replicates human bone, there has been a drive to explore other available models. Three-dimensional (3D) printing has risen in both popularity and availability, providing a new option in the creation of anatomically accurate bone models.
View Article and Find Full Text PDFHand Surg Rehabil
December 2024
Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, New York, NY, United States; Department of Surgery, Elmhurst Hospital Center, Elmhurst, NY, United States; Division of Plastic and Reconstructive Surgery, Icahn School of Medicine at Mount Sinai, New York, NY, United States. Electronic address:
Tendon-related complications comprise a significant portion of overall complications following volar locked plating of distal radius fractures. While much is known about the effect of prominent hardware in the volar and dorsal metaepiphyseal region of the distal radius, less is known about the effect of hardware prominence in the dorsal meta-diaphyseal region. The purpose of this anatomic study was to evaluate the safety of dorsal screw penetration at the proximal holes of volar locking plates.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!