Background: In a previous biomechanical study, eccentric glenospheres with more inferior position of the center of rotation were shown to improve range of motion and reduce the incidence of scapular notching after reverse total shoulder arthroplasty (RSA). The purpose of this study was to compare the clinical and radiological results of RSA using an eccentric glenosphere to those using a concentric glenosphere and to determine the usefulness of the eccentric glenosphere.
Methods: From 2009 to 2015, we performed a retrospective review of 20 consecutive patients who underwent RSA using a deltopectoral approach. Nine patients underwent RSA using a concentric glenosphere (group A) while 11 had an eccentric glenosphere (group B). The average follow-up period was 13.9 months (range, 12 to 18 months). All glenoid components were placed with 15° of inferior tilt. Clinical results were assessed using the visual analog pain scale score (VAS), the American Shoulder and Elbow Surgeon (ASES) score, the Korean shoulder scoring system (KSS), and the Constant score. On radiological evaluation, prosthesisscapular neck angle (PSNA), peg-glenoid rim distance (PGRD), scapular neck-inferior glenoshere rim distance (inferior glenoshpere overhang), acromion-greater tuberosity (AT) distance, glenoid-greater tuberosity (GT) distance, and severity of notching according to the Nerot-Sirveaux classification were assessed.
Results: The clinical results improved significantly in both groups, but there was no statistically significant difference between the two groups. A significant intergroup difference was observed with regard to PGRD (24.8 ± 1.6 mm for group A vs. 22.2 ± 1.9 mm for group B; = 0.002) and inferior glenosphere overhang (2.0 ± 1.7 mm for group A vs. 5.8 ± 1.6 mm for group B; = 0.000). Seven of 9 patients in group A developed notching compared with 2 of 11 patients in group B ( = 0.022). The other radiological parameters such as inferior tilt and AT and GT distances were not significantly different between two groups. Complications such as loosening and scapular fractures did not occur.
Conclusions: The eccentric glenosphere in RSA was more effective in reducing the rate of notching than the concentric glenosphere although clinical outcomes were not significantly different in the short-term follow-up.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5334032 | PMC |
http://dx.doi.org/10.4055/cios.2017.9.1.83 | DOI Listing |
Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.
Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.
J Clin Orthop Trauma
September 2024
Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.
Introduction: Increasing the impingement-free Range Of Movement (ROM) is crucial for improving patient's functional outcome and reducing the rate of scapular notching. The purpose of this study was to compare, in a virtual model of Reverse Shoulder Arthroplasty with glenoid lateralization (L-RSA): 1) the impingement-free range of movement (ROM) between 155° Grammont-style inlay stem and 135° flushlay stem; 2) the effect of glenosphere size and type (centered vs eccentric) on impingement-free range of movement (ROM) using a 135° Neck Shaft Angle (NSA) flushlay stem.
Materials And Methods: 200 CT-scans of patients undergoing shoulder replacement for Cuff tear Arthropathy were analyzed in the present study.
JBJS Essent Surg Tech
July 2024
Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland.
Background: Metallic lateralized-offset glenoid reverse shoulder arthroplasty (RSA) for cuff tear arthropathy combines the use of a metallic augmented baseplate with a metaphyseally oriented short stem design that can be applied at a 135° or 145° neck-shaft angle, leading to additional lateralization on the humeral side. Lateralization of the center of rotation decreases the risk of inferior scapular notching and improves external rotation, deltoid wrapping, residual rotator cuff tensioning, and prosthetic stability. Metallic increased-offset RSA (MIO-RSA) achieves lateralization and corrects inclination and retroversion while avoiding graft resorption and other complications of bony increased-offset RSA (BIO-RSA).
View Article and Find Full Text PDFClin Orthop Surg
April 2024
Department of Orthopaedic Surgery, Ewha Shoulder Disease Center, Ewha Womans University Seoul Hospital, Ewha Womans University School of Medicine, Seoul, Korea.
Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA.
Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E).
JSES Int
March 2024
Chirurgie de l'épaule et du coude, Service d'Orthopédie et de Traumatologie, Ensemble Hospitalier de la Côte, Morges, Switzerland.
Background: In reverse shoulder arthroplasty (RSA), the ideal combination of baseplate lateralization (BL), glenosphere size (GS), and glenosphere overhang (GOH) with a commonly used 145° neck shaft angle (NSA) is unclear. This is the first study evaluating correlations of body height (BH), humeral head size (HS), glenoid height (GH), and association of gender with best glenoid configurations for range of motion (ROM) maintaining anatomic lateralization (aLAT) for optimized muscle length in 145° and less distalized 135° RSA.
Methods: In this computer model study, 22 computed tomographies without joint narrowing were analyzed (11 male/female).