Development of advanced biantibiotic loaded bone cement spacers for arthroplasty associated infections.

Int J Pharm

Institute of Polymer Science and Technology, ICTP-CSIC, C/Juan de la Cierva 3, 28006 Madrid, Spain; CIBER, Health Institute Carlos III, C/Monforte de Lemos 3-5, Pabellón 11, 28029 Madrid, Spain.

Published: April 2017

The incidence increase of infections in patients with hip or knee implants with resistant pathogens (mainly some S. coagulase-negative and gram positive bacteria) demands advanced antibiotic loaded formulations. In this paper, we report the design of new biantibiotic acrylic bone cements for in situ delivery. They include a last generation antibiotic (daptomycin or linezolid) in combination with vancomycin and are performed based on a novel modification of the Palacos R acrylic bone cement, which is based on two components, a liquid (methyl methacrylate) and a solid (polymeric phase). Hence, the solid component of the experimental formulations include 45wt% of microparticles of poly(D,L-lactic-co-glycolic) acid, 55wt% of poly(methyl methacrylate) beads and supplements (10wt-% each) of antibiotics. These formulations provide a selective and excellent control of the local release of antibiotics during a long time period (up to 2 months), avoiding systemic dissemination. The antimicrobial activity of the advanced spacers tested against S. aureus shows that single doses would be enough for the control of the infection. In vitro biocompatibility of cements on human osteoblasts is ensured. This paper is mainly focused on the preparation and characterization of cements and the studies of elution kinetics and bactericidal effects. Developed formulations are proposed as spacers for the treatment of infected arthroplasties, but also, they could be applied in other antibiotic devices to treat relevant bone-related infection diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2017.02.066DOI Listing

Publication Analysis

Top Keywords

bone cement
8
acrylic bone
8
development advanced
4
advanced biantibiotic
4
biantibiotic loaded
4
loaded bone
4
cement spacers
4
spacers arthroplasty
4
arthroplasty associated
4
associated infections
4

Similar Publications

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Background: Kyphoplasty (KP) is a well-established procedure with a low complication risk, however, the procedure's safety in patients with comorbidities and in the setting of systemic infection remains uncertain with no clear guidelines. We present a unique case of KP in the setting of recurrent septicemia, which required subsequent salvage vertebrectomy.

Case Description: We present a clinical case of a 59-year-old diabetic male patient with a recent foot ulcer, positive for and .

View Article and Find Full Text PDF

Objectives: This study evaluates the effect of different irrigation solutions for postoperative pain in the regenerative endodontic treatments (RET) of necrotic teeth with open apex.

Materials And Methods: This study included necrotic, deeply carious lower molars of 42 patients. Access cavities of the teeth were opened and working lengths were measured at the first visit.

View Article and Find Full Text PDF

Purpose: This study investigated the synergistic effects of reduced graphene oxide (RGO) on the antibacterial activity of three calcium hydroxide-based intracanal medicaments with different vehicles.

Methods: Multispecies biofilms were cultured in a bovine root canal model. Intracanal medicaments containing nonaqueous vehicles, including N-methyl-2-pyrrolidone (NMP; CleaniCal), propylene glycol (PG; UltraCal XS), and polyethylene glycol (PEG; Calcipex II), were placed in the model.

View Article and Find Full Text PDF

Analyzing the chemical composition of different kinds of acrylic cement is necessary to understand their properties and suitability for curing bone defects. Conducting various chemical tests can give valuable insight into the composition, viscosity, and performance characteristics of each kind of cement, Therefore, our study aimed to find safety standards and the effectiveness of these products for medical applications. The polymeric characterization was determined by Nuclear Magnetic Resonance (H-NMR) spectroscopy and Fourier-transform infrared spectroscopy (FTIR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!