A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Humeral head sizing using extra-articular landmarks on conventional radiographs. | LitMetric

Humeral head sizing using extra-articular landmarks on conventional radiographs.

Surg Radiol Anat

South County Orthopedic Specialists, 24331 El Toro Road, #200, Laguna Woods, CA, 92637, USA.

Published: September 2017

Purpose: Proper humeral head (HH) sizing is critical to success in anatomic shoulder replacement for management of glenohumeral arthritis. In this study, we evaluate the accuracy and reliability of using non-articular landmarks on conventional radiographs for HH templating.

Methods: Anatomic HH replacement was performed on five non-arthritic shoulders, from fresh adult cadavers. Pre-operative and post-operative radiographs and 3-D CT scans were obtained. Humeral head size was determined using the articular surface and three extra-articular landmarks (inner aspect of the lateral cortex, the medial footprint of the rotator cuff, and the medial calcar). Two independent observers performed each measurement twice to evaluate reliability. The accuracy was assessed by subtracting the mean values from both the 3D-CT and the implanted HH size measurements.

Results: Intraclass correlation coefficient for Observer 1 and 2 for the three-point method showed excellent test-retest reliability 0.996 (95% CI 0.994-0.998) and 0.997 (95% CI 0.995-0.998), respectively. Inter-observer ICC for the three-point method was 0.996 (95% CI 0.994-0.997) showing high level of precision. The three-point method was overestimating the size of the HH (to 3D-CT) with 0.46 ± 0.61 mm on average. The three-point method predicted the size of the HH within 1 mm of the implanted head size showing very high accuracy. The center of rotation (COR) for the three-point method was within 1.34 mm of the (COR) of the articular surface.

Conclusion: The three-point measuring technique using conventional radiographs may be useful to predict the HH size using extra-articular landmarks within a small margin of error. This method is simple, cost effective and has high level of precision.

Level Of Evidence: Basic Science Study; Anatomic and Imaging Study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00276-017-1833-zDOI Listing

Publication Analysis

Top Keywords

three-point method
20
humeral head
12
extra-articular landmarks
12
conventional radiographs
12
head sizing
8
landmarks conventional
8
head size
8
0996 95%
8
showing high
8
high level
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!