A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Density-Based Clustering Approach to Motor Unit Potential Characterizations to Support Diagnosis of Neuromuscular Disorders. | LitMetric

Electrophysiological muscle classification involves characterization of extracted motor unit potentials (MUPs) followed by the aggregation of these MUP characterizations. Existing techniques consider three classes (i.e., myopathic, neurogenic, and normal) for both MUP characterization and electrophysiological muscle classification. However, diseased-induced MUP changes are continuous in nature, which make it difficult to find distinct boundaries between normal, myopathic, and neurogenic MUPs. Hence, MUP characterization based on more than three classes is better able to represent the various effects of disease. Here, a novel, electrophysio- logical muscle classification system is proposed, which considers a dynamic number of classes for characterizing MUPs. To this end, a clustering algorithm called neighbor- hood distances entropy consistency is proposed to find clusters with arbitrary shapes and densities in an MUP feature space. These clusters represent several concepts of MUP normality and abnormality and are used for MUP characterization instead of the conventional three classes. An examined muscle is then classified by embedding its MUP characterizations in a feature vector fed to an ensemble of support vector machine and nearest neighbor classifiers. For 103 sets of MUPs recorded in tibialis anterior muscles, the proposed system had a 97% electro-physiological muscle classification accuracy, which is significantly higher than in previous works.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2017.2673664DOI Listing

Publication Analysis

Top Keywords

muscle classification
16
three classes
12
mup characterization
12
motor unit
8
electrophysiological muscle
8
mup
8
mup characterizations
8
myopathic neurogenic
8
muscle
5
density-based clustering
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!