Comparing Intravenous Insertion Instructional Methods with Haptic Simulators.

Nurs Res Pract

Texas Woman's University, 6700 Fannin Street, Houston, TX 77030-2343, USA.

Published: January 2017

. The objective of this review was to compare traditional intravenous (IV) insertion instructional methods with the use of haptic IV simulators. . An integrative research design was used to analyze the current literature. . A search was conducted using key words intravenous (IV) insertion or cannulation or venipuncture and simulation from 2000 to 2015 in the English language. The databases included Academic Search Complete, CINAHL Complete, Education Resource Information Center, and Medline. . Whittemore and Knafl's (2005) strategies were used to critique the articles for themes and similarities. . Comparisons of outcomes between traditional IV instructional methods and the use of haptic IV simulators continue to show various results. Positive results indicate that the use of the haptic IV simulator decreases both band constriction and total procedure time. While students are satisfied with practicing on the haptic simulators, they still desire faculty involvement. . Combining the haptic IV simulator with practical experience on the IV arm may be the best practice for learning IV insertion. Research employing active learning strategies while using a haptic IV simulator during the learning process may reduce cost and faculty time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5303580PMC
http://dx.doi.org/10.1155/2017/4685157DOI Listing

Publication Analysis

Top Keywords

haptic simulators
16
intravenous insertion
12
instructional methods
12
methods haptic
12
haptic simulator
12
insertion instructional
8
haptic
7
comparing intravenous
4
insertion
4
simulators
4

Similar Publications

Integrating augmented reality (AR) and virtual reality (VR) into dental surgery education and practice has significantly advanced the precision and interactivity of dental training and patient care. This narrative review summarizes findings from extensive literature searches conducted in PubMed, Cochrane Library, and Embase, highlighting AR and VR technologies transformative impact and current applications. Research shows that AR improves surgical precision by offering real-time data overlays during procedures, leading to better outcomes in operations like dental implant placements.

View Article and Find Full Text PDF

Design and Evaluation of Augmented Reality-Enhanced Robotic System for Epidural Interventions.

Sensors (Basel)

December 2024

Surgical Performance Enhancement and Robotics (SuPER) Centre, Department of Surgery, McGill University, Montreal, QC H3A 0G4, Canada.

The epidural injection is a medical intervention to inject therapeutics directly into the vicinity of the spinal cord for pain management. Because of its proximity to the spinal cord, imprecise insertion of the needle may result in irreversible damage to the nerves or spinal cord. This study explores enhancing procedural accuracy by integrating a telerobotic system and augmented reality (AR) assistance.

View Article and Find Full Text PDF

Haptic Technology: Exploring Its Underexplored Clinical Applications-A Systematic Review.

Biomedicines

December 2024

Neuromodulation Center and Center for Clinical Research Learning, Spaulding Rehabilitation Hospital and Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA.

Background/objectives: Haptic technology has transformed interactions between humans and both tangible and virtual environments. Despite its widespread adoption across various industries, the potential therapeutic applications of this technology have yet to be fully explored.

Methods: A systematic review of randomized controlled trials (RCTs) and randomized crossover trials was conducted, utilizing databases such as PubMed, Embase, Cochrane Library, and Web of Science.

View Article and Find Full Text PDF

Background: Correct identification of the epidural space requires extensive training for technical proficiency. This study explores a novel bimanual haptic simulator designed for the precise insertion of an epidural needle based on loss-of-resistance (LOR) detection, providing realistic dual-hand force feedback.

Methods: The simulator, equipped with two haptic devices connected to a Tuohy needle and an LOR syringe, was designed to simulate the tissues' resistive forces felt by the user during the procedure, offer anatomical variability and record detailed performance metrics for personalized feedback.

View Article and Find Full Text PDF

Objective: Mixed-reality (MR) applications provide opportunities for technical rehearsal, education, and estimation of surgical performance without the risk of patient harm. In this study, the authors provide a structured literature review on the current state of MR applications and their effects on neurosurgery training. They also introduce an MR prototype for neurosurgical spine training.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!