The efficacy of two novel artificial vitreous body substitutes (VBS) consisting of highly biocompatible thiolated cross-linked hyaluronic acid (HA)-based hydrogels in comparison to silicone oil in a model of retinal detachment was investigated. Pars plana vitrectomy (23G) was performed in the right eye of 24 pigmented rabbits. Retinal detachment of two quadrants was induced by creating a small retinotomy near the vascular arcade and injecting balanced salt solution (BSS) subretinally. The retina was reattached by injecting air, which was followed by increasing the infusion pressure, and the retinal tear was treated by endolaser photocoagulation. At the end of the procedure, the eye was filled either with 5000-cs silicone oil (after fluid air exchange) or the respective hydrogel (with two different viscosities). Follow-up examination included slit lamp examination, funduscopy, intraocular pressure measurements (IOP), optical coherence tomography (OCT) and electroretinogram (ERG) measurements. After a maximum follow-up of four weeks both eyes were removed, examined macroscopically, photographed, and prepared for histology. Of the eight rabbits that received silicone oil, seven (87.5%) developed a recurrent retinal detachment with pronounced proliferative vitreoretinopathy within the first two weeks after surgery. In contrast, in the hydrogel treated eyes, the retina stayed attached in the majority of the cases (73.3%). IOP and retinal morphology were normal as long as the retina remained re-attached. In conclusions, this model of retinal detachment, both thiolated crosslinked hyaluronate hydrogels showed superior efficacy when compared to silicone oil. These hydrogels have a promising potential as novel vitreous body substitutes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5332068 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0172895 | PLOS |
Clin Ophthalmol
January 2025
Department of Ophthalmology, Cleveland Clinic Abu Dhabi, Abu Dhabi, United Arab Emirates.
Purpose: To evaluate the efficacy and safety of the Paul Glaucoma Implant (PGI) surgery in patients with secondary glaucomas.
Patients And Methods: Retrospective chart review of adult patients with medically recalcitrant secondary glaucoma who underwent PGI implantation at a single tertiary center between August 2022 and June 2023. The primary outcome measure was surgical success.
BMC Ophthalmol
January 2025
Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
Purpose: Proliferative vitreoretinopathy (PVR) is a complication of retinal detachment which requires multiple vitreoretinal surgical interventions and frequent use of oil endotamponade. In this study, we conducted an in-depth analysis of complications associated with the use of heavy silicone oil in the management of inferior PVR.
Methods: A retrospective cohort study of 20 eyes that underwent vitrectomy for inferior PVR with use of heavy silicone oil (Densiron 68) between March 2021 and October 2022 at Oxford Eye Hospital.
BMC Ophthalmol
January 2025
Dept. of Retina and Vitreous, Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, 560010, India.
Purpose: To report a rare case of a Coats-like response developing after vitreoretinal surgery for proliferative diabetic retinopathy (PDR) and its successful management with retinal laser photocoagulation and adjunctive intravitreal steroids.
Case Description: A 52-year-old woman with a five-year history of type 2 diabetes mellitus and hypertension presented with decreased vision in the left eye (counting fingers at 1 m). Examination revealed high-risk PDR in both eyes, with a subtotal macula-off combined retinal detachment in the left eye.
Langmuir
January 2025
Materials Science and Technology Division, CSIR - National Institute for Interdisciplinary Science and Technology, Thiruvananthapuram 695019, Kerala, India.
Meso/microporous nano silica modified with macromolecular polymers produces attractive hybrids that repel water and have a hydrophobic surface, making them highly effective for targeting and eliminating organic contaminants in aquatic environments. In this study, nano silica was functionalized with silicone oil, an oligomeric siloxane derivative, to produce a hydrophobic silica nano hybrid characterized by a non-wetting water contact angle of 139°. This hydrophobic hybrid nano silica showed a sustainable floating nature on water even in turbulent streams.
View Article and Find Full Text PDFCytometry A
January 2025
Materials Measurements Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
An emulsion of silicone oil droplets in aqueous buffer produces a distinctive series of peaks or resonances in the side scatter histogram in a flow cytometer. As many as 12 peaks are observed in the violet-side scatter channel at 405 nm, with half that number observed in the blue side scatter channel at 488 nm. Using the index of refraction of the oil and buffer, the wavelength of light, and the collection angle and gain of the instrument, we assign the peaks to specific diameters at which Mie resonances occur.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!