Purpose: We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness.
Methods: Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale.
Results: Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB + SPECT images (p < 0.0001).
Conclusions: 3D SPECT/CT fusion offers comparable diagnostic accuracy to 2D SPECT/CT fusion. The visual effect of 3D SPECT/CT fusion facilitates reduction of reading time compared to 2D SPECT/CT fusion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5397460 | PMC |
http://dx.doi.org/10.1007/s12149-017-1158-3 | DOI Listing |
Eur J Nucl Med Mol Imaging
December 2024
Department of Radiology, Graduate School of Medicine, Osaka University, Suita, Japan.
Hell J Nucl Med
December 2024
Department of Obstetrics and Gynecology, Shiyan Matenal and Child Health Hospital, Shiyan, Hubei, China.
Objective: To analyze the application value of standardized uptake value (SUV) in quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) based on the maximum expectation reconstruction algorithm for diagnosing benign and malignant bone lesions.
Subjects And Methods: A retrospective analysis was conducted on the clinical data of 83 patients suspected of bone metastasis who underwent quantitative SPECT/CT bone scans in our hospital from September 2023 to July 2024. A total of 91 high-metabolic bone lesions were outlined for SUV measurement, while the spinal SUV of patients with normal bone metabolism were outlined as the control group (46 vertebral bodies).
Clin Nucl Med
January 2025
From the Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Beijing, China.
Purpose: Accuracy in in vivo assessment of human epidermal growth factor receptor type 2 (HER2) status is crucial for predicting the response to HER2-targeted therapies in breast cancer. This study assessed the safety, feasibility, and diagnostic accuracy of 99mTc-ABH2, a reengineered affibody molecule with radionuclide labeling, for HER2 expression in breast cancer using SPECT/CT imaging, compared with 18F-FDG PET/CT.
Patients And Methods: Thirty-six patients suspected of primary breast cancer were enrolled in this prospective, single-center study from March to July in 2023.
Curr Med Imaging
November 2024
Department of Biomedical Engineering, Vignan's Foundation for Science, Technology, and Research, Guntur, Andhra Pradesh, 522213, India.
Introduction: Multimodal medical image fusion techniques play an important role in clinical diagnosis and treatment planning. The process of combining multimodal images involves several challenges depending on the type of modality, transformation techniques, and mapping of structural and metabolic information.
Methods: Artifacts can form during data acquisition, such as minor movement of patients, or data pre-processing, registration, and normalization.
Tomography
October 2024
Statistics Consulting Laboratory, BIO5 Institute, University of Arizona, Tucson, AZ 85719, USA.
Quantitative thresholds are helpful to define an abnormal DaT SPECT in patients with suspected nigrostriatal degenerative diseases (NSDD). The optimal DaTQUANT threshold for diagnostic accuracy of DaT SPECT across combined movement and cognitive disorder populations has been previously described. : We established optimal DaTQUANT thresholds that enhance the discrimination between dementia with Lewy bodies (DLB) and non-DLB dementia types, as well as between Parkinsonian syndromes (PS) and conditions not characterized by nigrostriatal degeneration (non-PS).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!