AI Article Synopsis

Article Abstract

In this paper, the effect of isotope-labeled analogs on the liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) measurement was evaluated based on the comparison research of electrospray ionization responses (ESI) and matrix effect of melamine, C-melamine, C+N-melamine, and N-melamine. The isotope-labeled melamines had similar ionization efficiency with melamine in the electrospray ionization source, but the intensity of corresponding quantitative fragment ions had distinctive differences. Based on the density functional theory at the B3LYP/6-311+G** level, this phenomenon was explained very well. The rare cleavage pathways of melamine, which just could be exactly identified by N-labeled melamines, resulted in the difference of quantitative fragment ions between N-labeled melamines and melamine. The interaction of ESI response between melamine and isotope-labeled melamines was investigated using MRM monitor mode. N-labeled melamine had significant ion inter-suppression effect on melamine, while C-labeled melamine had little influence on melamine. Finally, the influence of different isotope-labeled melamines on the LC-IDMS result was evaluated using the IDMS correction factor (θ). Taking the determination of melamine in milk powder as an example, the matrix effects of different isotope-labeled melamines and melamine had notable difference and the impact of this difference on the measurement results depended on the concentrations of analyte and matrix solution. It was worth noting that N-melamine exhibited significant ion suppression to melamine in matrix solution. The deviation of the results from IDMS method might reach 59% using N-melamine as internal standard in special matrix solution. Graphical Abstract The comparison of ESI responses of melamine, C-melamine, C+N-melamine and N-melamine.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-017-0263-4DOI Listing

Publication Analysis

Top Keywords

isotope-labeled melamines
16
melamine
14
melamine c-melamine
12
c-melamine c+n-melamine
12
c+n-melamine n-melamine
12
matrix solution
12
effects isotope-labeled
8
isotope-labeled analogs
8
lc-idms measurement
8
comparison esi
8

Similar Publications

In this paper, the effect of isotope-labeled analogs on the liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) measurement was evaluated based on the comparison research of electrospray ionization responses (ESI) and matrix effect of melamine, C-melamine, C+N-melamine, and N-melamine. The isotope-labeled melamines had similar ionization efficiency with melamine in the electrospray ionization source, but the intensity of corresponding quantitative fragment ions had distinctive differences. Based on the density functional theory at the B3LYP/6-311+G** level, this phenomenon was explained very well.

View Article and Find Full Text PDF

Study on diffusion behavior of analyte in an electrospray ionization source.

Rapid Commun Mass Spectrom

August 2016

Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing, 100013, China.

Rationale: Diffusion of an analyte is one of the main determinants of reduced sensitivity in an electrospray ionization (ESI) source. In this work, the relative responses of compounds and their stable isotope-labeled (SIL) products in different injection modes were compared to investigate the diffusion behavior of analytes in ESI, without influence of other factors.

Methods: Chloramphenicol (CAP) and D5 -CAP as well as melamine (Mel) and (13) C3 -Mel were used to illustrate the diffusion behavior in different operation modes and different ion sources, by comparing their relative responses in infusion mode and flow injection analysis (FIA) mode under variable temperature.

View Article and Find Full Text PDF

Rationale: Milk-derived ingredients are widely used around the world in the manufacturing of nutritional products. They are prone to economically motivated adulteration with nitrogenous compounds such as melamine and its analogs in order to increase the nitrogen content of these ingredients. The need to rapidly screen milk-derived ingredients to detect adulteration is of paramount public health concern.

View Article and Find Full Text PDF

A method for the rapid quantification of 9 potential nitrogen-rich economic adulterants (dicyandiamide, urea, biuret, cyromazine, amidinourea, ammeline, amidinourea, melamine, and cyanuric acid) in five milk and soy derived nutritional ingredients, i.e. whole milk powder, nonfat dry milk, milk protein concentrate, sodium caseinate, and soy protein isolate has been developed and validated for routine use.

View Article and Find Full Text PDF

This paper reports the development and validation of a methodology for the low-level quantification of melamine and cyanuric acid in limited samples of rat serum. The methodology, based upon ion-exchange solid phase extraction (SPE) and ultra-performance liquid chromatography (UPLC) coupled with electrospray tandem mass spectrometry (MS/MS) in multiple reaction monitoring (MRM) mode, relies on the use of stable isotope-labeled internal standards and requires only 15 μL samples of serum. The method provides a recovery of 80-110% of melamine with a signal suppression of ca.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!