Objectives: To compare the accuracy of the INTERGROWTH-21st (IG-21) with the Italian Society of Ultrasound in Obstetrics and Gynecology (SIEOG) abdominal circumference (AC) standards in the detection of small-for-gestational-age (SGA) fetuses in a high-risk population.

Material And Methods: Our study included all pregnant patients with an increased risk of placental insufficiency that were seen in two Italian university hospitals between 2014 and 2015. The accuracy of IG-21 and SIEOG AC standards in the detection of SGA neonates was analyzed by means of the area under the receiver operating characteristic curve (ROC-AUC) at 4 gestational age intervals (24-27, 28-31, 32-35, >35 weeks).

Results: We enrolled 428 patients (278 Italians). There was no significant difference between the ROC-AUC of AC according to IG-21 and SIEOG standards for all birthweight thresholds and gestational intervals that were considered. The diagnostic performance was similar in Italian and non-Italian patients. The accuracy was, however, limited, with values of ROC-AUC ranging between 0.80 and 0.89.

Conclusions: The IG-21 and SIEOG AC standards are interchangeable for the diagnosis of SGA fetuses. The diagnostic accuracy is, however, limited. We provide figures that can be used to stratify the probability that an infant will be SGA in an obstetric population at increased risk of growth restriction.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000457121DOI Listing

Publication Analysis

Top Keywords

ig-21 sieog
12
sieog standards
12
abdominal circumference
8
standards detection
8
sga fetuses
8
increased risk
8
accuracy limited
8
standards
5
clinical validation
4
validation intergrowth-21st
4

Similar Publications

Objectives: To compare the accuracy of the INTERGROWTH-21st (IG-21) with the Italian Society of Ultrasound in Obstetrics and Gynecology (SIEOG) abdominal circumference (AC) standards in the detection of small-for-gestational-age (SGA) fetuses in a high-risk population.

Material And Methods: Our study included all pregnant patients with an increased risk of placental insufficiency that were seen in two Italian university hospitals between 2014 and 2015. The accuracy of IG-21 and SIEOG AC standards in the detection of SGA neonates was analyzed by means of the area under the receiver operating characteristic curve (ROC-AUC) at 4 gestational age intervals (24-27, 28-31, 32-35, >35 weeks).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!