A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly Stable and Sensitive Nucleic Acid Amplification and Cell-Phone-Based Readout. | LitMetric

Highly Stable and Sensitive Nucleic Acid Amplification and Cell-Phone-Based Readout.

ACS Nano

Department of Bioengineering, ‡Department of Electrical Engineering, ∥Department of Pathology & Laboratory Medicine, ^Department of Mechanical and Aerospace Engineering, ⊥California NanoSystems Institute, and ¶Jonsson Comprehensive Cancer Center, University of California Los Angeles, Los Angeles, California 90095, United States.

Published: March 2017

Key challenges with point-of-care (POC) nucleic acid tests include achieving a low-cost, portable form factor, and stable readout, while also retaining the same robust standards of benchtop lab-based tests. We addressed two crucial aspects of this problem, identifying a chemical additive, hydroxynaphthol blue, that both stabilizes and significantly enhances intercalator-based fluorescence readout of nucleic acid concentration, and developing a cost-effective fiber-optic bundle-based fluorescence microplate reader integrated onto a mobile phone. Using loop-mediated isothermal amplification on lambda DNA we achieve a 69-fold increase in signal above background, 20-fold higher than the gold standard, yielding an overall limit of detection of 25 copies/μL within an hour using our mobile-phone-based platform. Critical for a point-of-care system, we achieve a >60% increase in fluorescence stability as a function of temperature and time, obviating the need for manual baseline correction or secondary calibration dyes. This field-portable and cost-effective mobile-phone-based nucleic acid amplification and readout platform is broadly applicable to other real-time nucleic acid amplification tests by similarly modulating intercalating dye performance and is compatible with any fluorescence-based assay that can be run in a 96-well microplate format, making it especially valuable for POC and resource-limited settings.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsnano.6b08274DOI Listing

Publication Analysis

Top Keywords

nucleic acid
20
acid amplification
12
nucleic
5
acid
5
highly stable
4
stable sensitive
4
sensitive nucleic
4
amplification
4
amplification cell-phone-based
4
readout
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!