A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Artifact-Free and Detection-Profile-Independent Higher-Order Fluorescence Correlation Spectroscopy for Microsecond-Resolved Kinetics. 1. Multidetector and Sub-Binning Approach. | LitMetric

Fluorescence correlation spectroscopy (FCS) is a powerful tool in the time-resolved analysis of nonreacting or reacting molecules in solution, based on fluorescence intensity fluctuations. However, conventional (second-order) FCS alone is insufficient to measure all parameters needed to describe a reaction or mixture, including concentrations, fluorescence brightnesses, and forward and reverse rate constants. For this purpose, correlations of higher powers of fluorescence intensity fluctuations can be calculated to yield additional information from the single-photon data stream collected in an FCS experiment. To describe systems of diffusing and reacting molecules, considering cumulants of fluorescence intensity results in simple expressions in which the reaction and diffusion parts factorize. The computation of higher-order correlations in experiments is hindered by shot-noise and common detector artifacts, the effects of which become worse with increasing order. In this article, we introduce a technique to calculate artifact-free higher-order correlation functions with improved time resolution, and without any need for modeling and calibration of detector artifacts. The technique is formulated for general multidetector experiments and verified in both two-detector and single-detector configurations. Good signal-to-noise ratio is achieved down to 1 μs in correlation curves up to order (2, 2). This capability makes possible a variety of new measurements including multicomponent analysis and fast reaction kinetics, as demonstrated in a companion article (10.1021/acs.jpcb.7b00408).

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.jpcb.7b00407DOI Listing

Publication Analysis

Top Keywords

fluorescence intensity
12
fluorescence correlation
8
correlation spectroscopy
8
reacting molecules
8
intensity fluctuations
8
detector artifacts
8
fluorescence
6
artifact-free detection-profile-independent
4
detection-profile-independent higher-order
4
higher-order fluorescence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!