A simple standard technique for labyrinthectomy in the rat: A methodical communication with a detailed description of the surgical process.

Physiol Int

1 Experimental Research Department and Department of Human Physiology, Semmelweis University, Budapest, Hungary.

Published: September 2016

Aims Labyrinthectomized rats are suitable models to test consequences of vestibular lesion and are widely used to study neural plasticity. We describe a combined microsurgical-chemical technique that can be routinely performed with minimum damage. Methods Caudal leaflet of the parotis is elevated. The tendinous fascia covering the bulla is opened frontally from the sternomastoid muscle's tendon while sparing facial nerve branches. A 4 mm diameter hole is drilled into the bulla's hind lower lateral wall to open the common (in rodents) mastoid-tympanic cavity. The cochlear crista (promontory) at the lower posterior part of its medial wall is identified as a bony prominence. A 1 mm diameter hole is drilled into its lower part. The perilymphatic/endolymphatic fluids with tissue debris of the Corti organ are suctioned. Ethanol is injected into the hole. Finally, 10 µL of sodium arsenite solution (50 µM/mL) is pumped into the labyrinth and left in place for 15 min. Simple closure in two layers (fascia and skin) is sufficient. Results and conclusion All rats had neurological symptoms specific for labyrinthectomy (muscle tone, body position, rotatory movements, nystagmus, central deafness). Otherwise, their behavior was unaffected, drinking and eating normally. After a few days, they learned to balance relying on visual and somatic stimuli (neuroplasticity).

Download full-text PDF

Source
http://dx.doi.org/10.1556/2060.103.2016.3.8DOI Listing

Publication Analysis

Top Keywords

diameter hole
8
hole drilled
8
simple standard
4
standard technique
4
technique labyrinthectomy
4
labyrinthectomy rat
4
rat methodical
4
methodical communication
4
communication detailed
4
detailed description
4

Similar Publications

Background And Objectives: Rebound pain (RP), characterised by an acute increase in pain levels, is usually observed after the effects of block anaesthesia have subsided. Severe RP can cause adverse effects, thus affecting patient prognosis. In this study, we investigated the incidence of RP and its risk factors after intercostal nerve block in three-port thoracoscopic surgery to provide a clinical basis for identifying high-risk patients and providing early intervention.

View Article and Find Full Text PDF

A signal-processing algorithm for the detailed determination of delamination in multilayer structures is proposed in this work. The algorithm is based on calculating the phase velocity of the Lamb wave A mode and estimating this velocity dispersion. Both simulation and experimental studies were conducted to validate the proposed technique.

View Article and Find Full Text PDF

Simulation Research on Low-Frequency Magnetic Noise in Fe-Based Nanocrystalline Magnetic Shields.

Materials (Basel)

January 2025

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.

Depending on high permeability, high Curie temperature, and low eddy current loss noise, nanocrystalline alloys, as the innermost layer, exhibit great potential in the construction of cylindrical magnetic shielding systems with a high shielding coefficient and low magnetic noise. This study compares a magnetic noise of 1 Hz, simulated by the finite element method (FEM), of a cylindrical nanocrystalline magnetic shield with different structural parameters based on the measured initial permeability of commercial Fe-based nanocrystalline (1K107). The simulated results demonstrate that the magnetic noise is irrelevant to the pump and probe hole diameter.

View Article and Find Full Text PDF

The electrochemical cutting technique, utilizing electrolyte flushing through micro-hole arrays in the radial direction of a tube electrode, offers the potential for cost-effective and high-surface-integrity machining of large-thickness, straight-surface structures of difficult-to-cut materials. However, fabricating the array of jet micro-holes on the tube electrode sidewall remains a significant challenge, limiting the broader application of this technology. To enhance the efficiency and quality of machining these jet micro-holes on the tube sidewall, a helical electrode electrochemical drilling method assisted by anode vibration has been proposed.

View Article and Find Full Text PDF

Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!