Prediction of the true IOL position.

Br J Ophthalmol

Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital, Vienna, Austria.

Published: October 2017

Purpose: To develop algorithms for preoperative estimation of the true postoperative intraocular lens (IOL) position to be used for IOL power calculation.

Setting: Moorfields Eye Hospital NHS Foundation Trust, London, UK.

Methods: Fifty patients were implanted randomly with a 3-piece IOL model in one eye and a 1-piece model in the other eye. Preoperatively, the IOLMaster was used to determine axial length, anterior chamber depth and mean corneal radius. Lens thickness and corneal width were measured with the ACMaster. Postoperative IOL position was measured with the ACMaster. Partial least squares (PLS) regression analysis of IOL position in terms of preoperative parameters was performed with a commercially available software package.

Results: The PLS regression analysis showed that age, refraction, corneal width, lens thickness and corneal radius are not significant predictors of postoperative position of the anterior IOL surface, while axial length and in particular anterior chamber depth are. Regression relationships in terms of the above-mentioned predictors were determined for the two models implanted. Surprisingly, it turned out that the position of the posterior IOL surface could be described by a single regression relationship valid for both models. The residual SD for prediction of IOL position was about 0.17 mm for all relationships.

Conclusions: Accurate relationships to determine the true postoperative IOL position were obtained. In addition to axial length and corneal radius, which are required for the IOL power calculation as such, they require measurement of preoperative anterior chamber depth only.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2016-309543DOI Listing

Publication Analysis

Top Keywords

iol position
24
axial length
12
anterior chamber
12
chamber depth
12
corneal radius
12
iol
11
position
8
true postoperative
8
iol power
8
model eye
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!