Statement Of Problem: The use of digital intraoral scanners is increasing; however, evidence of its precision in making crown impressions clinically remains scarce. Patients should also feel more comfortable with digital impressions, but only a few studies evaluating this subject have been performed.
Purpose: The purpose of this clinical study was to evaluate the marginal fit of monolithic zirconia crowns and patients' preferences for digital impressions versus polyvinyl siloxane (PVS) impressions.
Material And Methods: Sixteen participants with indications for single molar crowns were included. After crown preparation, digital impressions by intraoral scanner and PVS impressions were made. The participants were asked to complete a 6-item questionnaire with a visual analog scale related to perceptions of each of the following topics: time involved, taste/smell, occlusal registration, size of impression tray/scanner, gag reflex, and overall preference. Computer-aided design and computer-aided manufacturing monolithic zirconia crowns were fabricated from both impressions. The crowns were evaluated intraorally, and a blinded examiner measured the marginal discrepancy of silicone replicas under a stereomicroscope. Intraexaminer reliability was evaluated by calculating the intraclass correlation coefficient. Data for patients' preferences and marginal discrepancies were analyzed using the paired t test (α=.05).
Results: Visual analog scale scores for digital impressions were statistically significantly higher than those for PVS impressions in every topic (P<.05), except for occlusal registration. The results showed excellent reliability of the examiner with an intraclass correlation coefficient of .996. No significant difference was found in marginal discrepancies between the PVS group and the digital group on all sides (P>.05).
Conclusions: No differences were found in the clinical marginal fit of zirconia crowns fabricated from either digital impressions compared with PVS impressions. Furthermore, patients' satisfaction with digital impressions was significantly higher than with conventional impressions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2016.10.019 | DOI Listing |
J Dent Sci
January 2025
School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Background/purpose: Identifying crestal bone level (CBL) on the buccal and lingual aspects poses challenges in conventional dental radiographs. Given that optical coherence tomography (OCT) has the capability to non-invasively provide in-depth information about the periodontium, this in vitro study aimed to assess whether OCT can effectively identify periodontal landmarks and measure CBL in the presence of gingiva.
Materials And Methods: An in-house handheld scanning probe connected to a 1310-nm swept-source OCT (SS-OCT) system, along with self-developed algorithms were employed to measure the CBL in dental models with artificial gingiva.
J Dent Sci
January 2025
School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Background/purpose: The performance of intraoral scanners (IOSs) relies on the operator's skills. However, whether operator experience influences IOS accuracy remains unclear. This study investigated the effect of operator experience on the trueness accuracy and time-based efficiency of IOSs.
View Article and Find Full Text PDFAim: This study investigated the accuracy of intraoral scanner (IOS) based on different image acquisition technologies in the field of presurgical-orthopedictreatment (PSOT) in neonates with cleft.
Methods: Dental cast models of clinical situations representing unilateral cleft-lip-palate(UCLP), bilateral cleft-lippalate( BCLP) and cleft-palate(CP) with reference PEEK-scanbodies (Cares RC Mono-Scankörper, Straumann, Switzerland) were scanned utilizing four IOS systems: CareStream-CS3600®(CS), Medit-i500®(MD), Cerec-Omnicam®(SO), 3Shape-Trios-3®(TS). One calibrated operator made 5 scans from each model using each IOS (N=60).
Purpose: This in vitro study investigates the accuracy of digital impressions taken with different dental materials. It compares the scan accuracy and trueness of a handheld scanner operated by an experienced clinician, a handheld scanner operated by a robotic arm, and a tabletop scanner. By measuring the number of triangles, average degree, and vertices within the three groups, conclusions about the accuracy of different scanning methods on digital models can be drawn.
View Article and Find Full Text PDFInt J Clin Pediatr Dent
December 2024
Department of Pediatric Dentistry, Faculty of Dental Medicine, Universitas Airlangga, Surabaya, Indonesia.
Aims And Background: This study aimed to assess the accuracy of digital intraoral scans in capturing the three-dimensional (3D) surface of teeth and dental arches in mixed dentition, compared with conventional plaster models. Intraoral scanning technology has seen rapid advancements in recent years, revolutionizing orthodontic and dental practices. However, its accuracy in mixed dentition remains a subject of investigation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!