Background: Outdoor production of poultry is rapidly increasing, which could be associated with increased risks for exposure to different environmental sources of Salmonella. We report a comparison on the occurrence of Salmonella during 2007-2015 in broilers and laying hens in outdoor and indoor production subjected to the same requirements for the prevention and control of Salmonella as applied in Sweden.
Results: Our results give no indication that, during the period studied, the exposure to Salmonella in outdoor poultry production was higher than in the indoor production. The annual incidence of Salmonella infected flocks in outdoor production remained at a very low and at a similar level as for indoor production. For laying hens the annual proportion of birds in test positive flocks ranged from 0 to 1.3% for indoor production from 0 to 2.0% for outdoor production. For broilers the proportion of Salmonella infected flocks (2013-2015) was 0.16% for indoor, and 0% in outdoor production. The difference was not statistically significant and was further reduced when flocks infected due to vertical transmission or from a hatchery source were excluded. It should, however, be considered that the number of outdoor flocks included in this evaluation is very small and continuous evaluation is needed.
Conclusions: New animal production systems, including those driven by consumer and welfare demands, may be associated with a higher risk for the exposure of potential pathogens to food animals and possibly also subsequent outbreaks of food borne infections. In this study no increase in the risk for exposure of flocks to Salmonella in outdoor poultry production was found. The situation may well change and the possibility of Salmonella contamination in outdoor poultry production requires continuous attention.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5320760 | PMC |
http://dx.doi.org/10.1186/s13028-017-0281-4 | DOI Listing |
ACS EST Air
January 2025
Lyles School of Civil & Construction Engineering, Purdue University, West Lafayette, Indiana 47907, United States.
Commercial HVAC systems intended to mitigate indoor air pollution are operated based on standards that exclude aerosols with smaller diameters, such as ultrafine particles (UFPs, D ≤ 100 nm), which dominate a large proportion of indoor and outdoor number-based particle size distributions. UFPs generated from occupant activities or infiltrating from the outdoors can be recirculated and accumulate indoors when they are not successfully filtered by an air handling unit. Monitoring UFPs in real occupied environments is vital to understanding these source and mitigation dynamics, but capturing their rapid transience across multiple locations can be challenging due to high-cost instrumentation.
View Article and Find Full Text PDFInfect Dis Model
June 2025
Shanghai Institute of Infectious Disease and Biosecurity, School of Public Health, Fudan University, Shanghai, People's Republic of China.
Introduction: Social contact patterns significantly influence the transmission dynamics of respiratory pathogens. Previous surveys have quantified human social contact patterns, yielding heterogeneous results across different locations. However, significant gaps remain in understanding social contact patterns in rural areas of China.
View Article and Find Full Text PDFMalar J
January 2025
RBM Partnership Vector Control Working Group, Chem du Pommier 40, 1218, Le Grand-Saconnex, Switzerland.
Background: Global progress toward malaria elimination and eradication goals has stagnated in recent years, with many African countries reporting increases in malaria morbidity and mortality. Insecticide-treated nets and indoor residual spraying are effective, but the emergence and increased intensity of insecticide resistance and the challenge of outdoor transmission are undermining their impact. New tools are needed to get back on track towards global targets.
View Article and Find Full Text PDFSmall
January 2025
College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, China.
Solar desalination shows promise in tackling freshwater shortages, but challenges arise from the trade-off between water transportation and heat supply, affecting evaporators' efficiency and salt resistance. Additionally, intermittent nature of solar radiation significantly diminishes overall evaporative performance. This study presents dual-gradient heating solar evaporator for efficient desalination.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, South Korea.
Molecular diagnosis limitations, including complex treatment processes, low cost-effectiveness, and operator-dependent low reproducibility, interrupt the timely prevention of disease spread and the development of medical devices for home and outdoor uses. A newly fabricated gold nanopillar array-based film is presented for superior photothermal energy conversion. Magnifying the metal film surface-to-volume ratio increases the photothermal energy conversion efficiency, resulting in a swift reduction in the gene amplification reaction time.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!