To ensure similar primary implant stability measured by resonance frequency analysis (RFA) could be obtained in different jawbone densities by using a specific surgical drilling protocol and, to correlate those RFA measurements with factors related to the implant design, width, and length, we are performed a 1-year prospective clinical study was carried out using 27 subjects. A total of 67 hydrophilic titanium implants were placed using a standard 2-stage implant placement protocol. The bone type at each implant site was determined by evaluation of a preoperative, high-resolution cone beam computerized tomography (CBCT) scan. A modified drilling protocol was used in softer bone (types 2, 3, and 4) that allowed for greater implant thread contact with the surrounding bone. The implant stability quotient (ISQ) was measured at 4 different times during the study: initially it was determined immediately after implant placement, then again at stage 2 uncovering surgery, then at 6 months' postplacement and, and finally at 1 year postplacement. Data collected immediately after implant surgery demonstrated a high correlation (R = .99) between the ISQ and bone type classification. An overall trend toward a higher ISQ was found over the 1-year study period for all types of bone. Implants remained clinically and radiographically stable during the 1-year study period. Our data allow conclude that the primary stability of 2-staged loaded implants placed in different bone types can be optimized by applying this surgical drilling protocol during the implant placement. The ISQ method was found to be a reliable predictor of implant stability.

Download full-text PDF

Source
http://dx.doi.org/10.1563/aaid-joi-D-16-00159DOI Listing

Publication Analysis

Top Keywords

implant stability
16
drilling protocol
12
implant placement
12
implant
11
stability quotient
8
surgical drilling
8
bone type
8
bone types
8
1-year study
8
study period
8

Similar Publications

Objectives: To evaluate the efficacy, safety, and stability of EyeCryl Phakic intraocular lens (IOL) implantation.

Methodology: This retrospective study was conducted in Maghrabi Hospital in Medina to review 31 patients who underwent posterior chamber phakic IOL (EyeCryl Phakic IOL) for surgical correction of myopia or astigmatism. The data were collected from patient medical records after obtaining their consents.

View Article and Find Full Text PDF

Background: This video article describes the use of bone-anchored prostheses for patients with transtibial amputations, most often resulting from trauma, infection, or dysvascular disease. Large studies have shown that about half of all patients with a socket-suspended artificial limb experience limited mobility and limited prosthesis use because of socket-related problems. These problems occur at the socket-residual limb interface as a result of a painful and unstable connection, leading to an asymmetrical gait and subsequent pelvic and back pain.

View Article and Find Full Text PDF

While silk fibroin (SF) obtained from silkworm cocoons is expected to become a next-generation natural polymer, a fabrication method for SF-based artificial nerve conduits (SFCs) has not yet been established. Here, we report a bioresorbable SFC, fabricated using a novel freeze-thaw process, which ensures biosafety by avoiding any harmful chemical additives. The SFC demonstrated favorable biocompatibility (high hydrophilicity and porosity with a water content of > 90%), structural stability (stiffness, toughness, and elasticity), and biodegradability, making it an ideal candidate for nerve regeneration.

View Article and Find Full Text PDF

Enhanced production, functionalization, and applications of polyhydroxyalkanoates from organic waste: A review.

Int J Biol Macromol

January 2025

Department of Chemical and Environmental Engineering and Pro-Vice-Chancellor (Planning & Resources), University of Mauritius, Reduit, Mauritius.

Polyhydroxyalkanoates (PHAs) represent a promising class of biodegradable polyesters synthesized by various microorganisms as energy storage compounds. Their versatility and environmental friendliness make them potential candidates for replacing conventional plastics across numerous applications. However, challenges such as limited mechanical properties, high production costs, and thermal instability have hindered their widespread adoption.

View Article and Find Full Text PDF

Titanium dioxide nanotube arrays (TNTs) generated in situ on the surface of dental implants have been shown to enhance bone integration for load-bearing support while managing load distribution and energy dissipation to prevent bone resorption from overload. However, their inadequate stability limits the clinical use of conventional TNTs. This study introduces an innovative approach to improve the mechanical stability of TNTs while maintaining their bone-integration efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!