A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Corail stem as a reverse hybrid - survivorship and x-ray analysis at 10 years. | LitMetric

Background: The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA have been sparsely described.We report our experience of reverse hybrid THA, using the Elite plus polyethylene cemented cup together with the Corail fully hydroxyapatite-coated uncemented stem and a 28-mm alumina ceramic head.

Patients And Methods: 132 consecutive reverse hybrid hip arthroplasties were performed from January 2000 to December 2003 in 126 patients with a mean age of 54.3 years (28-65). All patients were routinely reviewed at 3 months, 1, 5, 7 and 10 years postoperatively. At each follow-up patients were seen either by a consultant orthopaedic surgeon or a senior trainee. Anteroposterior pelvic and lateral x-rays of the hip were taken at each visit. To estimate the survival of the THAs we used the Kaplan-Meier method with 95% confidence interval (CI). Logistic regression analysis was performed to determine which factors affected the presence of radiolucency around the femoral stem.

Results: The mean follow-up was 11.1 years (9.0-14.2). 1 patient was lost to follow-up, and 7 patients were deceased at the time of 10-year follow up. At 10 years 7 patients have had further surgery. 5 for infection, 1 periprosthetic femoral fracture and 1 heterotopic bone formation. All stems were classified as well fixed. 2 cups were defined as loose at 10 years. 1 patient is scheduled for revision the other refused revision. The clinical outcome and radiological findings were assessed in 123 hips. The mean Harris Hip Score was 94 (35-100) at 10 years and the mean WOMAC score was 89 (30.2-100).

Conclusions: We report good results with respect to clinical outcome and survival of the reverse hybrid concept in patients younger than 65. A successful outcome depends on meticulous preoperative planning, use of modern cementing techniques in the acetabulum and experience in implanting an uncemented stem.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380087PMC
http://dx.doi.org/10.5301/hipint.5000477DOI Listing

Publication Analysis

Top Keywords

reverse hybrid
20
uncemented stem
12
cemented cup
8
hybrid tha
8
follow-up patients
8
clinical outcome
8
years
7
patients
6
reverse
5
hybrid
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!