Objectives: To analyze the diagnostic accuracy of conventional and digital radiographic images and the impact of digital filters in evaluating the bone-implant interface.

Methods: Titanium implants were inserted into 74 fresh bovine ribs blocks, 37 fitting tight to the bone walls (simulating the existence of osseointegration) and 37 with a gap of 0.125 mm (simulating a failure in the osseointegration process). Periapical radiographs were taken with conventional film and two phosphor plate systems [VistaScan (Dürr Dental, Bietigheim-Bissingen, Germany) and Express (Instrumentarium, Tuusula, Finland)]. Digital radiographs were investigated with and without enhancement filters. Three blinded examiners assessed the images for the presence of juxtaposition in the bone-implant interface using a five-point Likert scale. Sensitivity, specificity and the area under the receiver-operating characteristic curve (AUC) and its 95% confidence interval (CI) were calculated for each variable. Intraexaminer and interexaminer agreements were analyzed using Kendall's concordance test.

Results: Intraexaminer and interexaminer agreements were >0.80 for both digital and conventional images. Conventional radiographs (AUC = 0.963/CI = 0.891 to 0.993) and digital images with high enhancement filters such as Caries2 (AUC = 0.964/CI = 0.892 to 0.993), Endo (AUC = 0.952/CI = 0.875 to 0.988) and Sharpen3 (AUC = 0.894/CI = 0.801 to 0.954) showed the greatest accuracy for evaluating the bone-implant interface. Original images from both digital systems and the further enhancement filters tested showed low sensitivity for the diagnosis task tested.

Conclusions: Conventional radiographs or digital radiographs with high-pass filters could help enhance diagnosis on implant-bone interface.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595032PMC
http://dx.doi.org/10.1259/dmfr.20160296DOI Listing

Publication Analysis

Top Keywords

enhancement filters
12
evaluating bone-implant
8
digital radiographs
8
bone-implant interface
8
intraexaminer interexaminer
8
interexaminer agreements
8
conventional radiographs
8
digital
7
conventional
5
images
5

Similar Publications

Rapid and Environment-Friendly LC-MS/MS for Simultaneous Analysis of Amino Acids in Veterinary Medicine.

Vet Med Sci

January 2025

Animal Disease Diagnosis Division, Animal and Plant Quarantine Agency (APQA), Ministry of Agriculture, Food and Rural Affairs, Gimcheon-si, Republic of Korea.

Background: Amino acid supplements are crucial for animal health and productivity. Traditional analysis methods face limitations like complexity, long testing times and toxic reagents. Therefore, a more efficient and reliable method is needed.

View Article and Find Full Text PDF

Use of and extracts as alternatives to organic filter in photoprotective formulations.

Nat Prod Res

January 2025

Laboratory of Chemistry-Biochemistry-Cosmetic Science, Section of Aesthetics and Cosmetic Science, Department of Biomedical Sciences, School of Health and Care Sciences, University of West Attica, Athens, Greece.

Recently, the cosmetic and pharmaceutical industries have aimed to reduce the concentration of EU-approved organic filters in their products by incorporating more natural ingredients. The goal is to find effective SPF boosters from plants while maintaining high protection levels and adhering to ecological and public health standards. This study focuses on developing a sunscreen formulation that replaces the organic filter EHMC (2-ethylhexyl-4-meth-oxycinnamate) with extracts from and/or oil.

View Article and Find Full Text PDF

Geometric Feature Characterization of Apple Trees from 3D LiDAR Point Cloud Data.

J Imaging

December 2024

Department of Agricultural Machinery Engineering, Graduate School, Chungnam National University, Daejeon 34134, Republic of Korea.

The geometric feature characterization of fruit trees plays a role in effective management in orchards. LiDAR (light detection and ranging) technology for object detection enables the rapid and precise evaluation of geometric features. This study aimed to quantify the height, canopy volume, tree spacing, and row spacing in an apple orchard using a three-dimensional (3D) LiDAR sensor.

View Article and Find Full Text PDF

Enhancing Virus Filter Performance Through Pretreatment by Membrane Adsorbers.

Membranes (Basel)

January 2025

Ralph E. Martin Department of Chemical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.

Virus filtration is used to ensure the high level of virus clearance required in the manufacture of biopharmaceutical products such as monoclonal antibodies. Flux decline during virus filtration can occur due to the formation of reversible aggregates consisting of self-assembled monomeric monoclonal antibody molecules, particularly at high antibody concentrations. While size exclusion chromatography is generally unable to detect these reversible aggregates, dynamic light scattering may be used to determine their presence.

View Article and Find Full Text PDF

Electro-conductive membranes coupled with a low-voltage electric field can enhance pollutant removal and mitigate membrane fouling, demonstrating significant potential for electrified wastewater treatment. However, efficient fabrication of conductive membranes poses challenges. An in situ oxidative polymerization approach was applied to prepare PVDF-based conductive membranes (PVDF-CMs) and response surface methodology (RSM) was adopted to optimize modification conditions enhancing membrane performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!