Background: Although numerous suture-button fixation techniques for acromioclavicular (AC) joint reconstruction have been validated with biomechanical testing in the superior direction, clinical reports continue to demonstrate high rates of construct slippage and breakage.

Purpose: To compare the stability of a novel closed-loop double Endobutton construct with a commercially available cortical button system in both the axial and superior directions.

Study Design: Controlled laboratory study.

Methods: Six matched pairs of fresh-frozen cadaveric upper extremities were anatomically dissected and prepared to simulate a complete AC joint dislocation. One side of each pair was reconstructed with the double Endobutton (DE) construct and other side with the dog bone button (DB) construct. The specimens were then tested using a materials testing machine, determining initial superior and axial displacements with a preload, and then cyclically loaded in the axial direction with 70 N for 5000 cycles. Displacement was again measured with the same preloads at fixed cycle intervals. The specimens were then loaded superiorly to failure.

Results: At 5000 cycles, the mean axial displacement was 1.7 mm for the DB group and 1.2 mm for the DE group ( = .19), and the mean superior displacement was 1.1 mm for the DB group and 0.7 mm for the DE group ( = .32). Load at failure was similar (558 N for DE, 552 N for DB; = .96). There was no statistically significant difference in the modes of failure.

Conclusion: Biomechanical testing of both constructs showed similar fixation stability after cyclical axial loading and similar loads to failure.

Clinical Relevance: The strength of both constructs after cyclical loading in the axial plane and load-to-failure testing in the superior plane validate their continued clinical use for achieving stability in AC joint reconstruction procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5298557PMC
http://dx.doi.org/10.1177/2325967116674668DOI Listing

Publication Analysis

Top Keywords

joint reconstruction
12
cortical button
8
acromioclavicular joint
8
biomechanical testing
8
testing superior
8
double endobutton
8
endobutton construct
8
5000 cycles
8
displacement group
8
group group
8

Similar Publications

Introduction: This paper examines the use of local antibiotic therapy in one-stage septic revision surgery for late periprosthetic joint infections (PJIs). This case study suggests that morselized bone allografts impregnated with antibiotics in powder form are a preferable alternative to polymethyl methacrylate (PMMA) because they can generate higher local antibiotic concentrations. Current research also recommends using vancomycin and aminoglycosides as the preferred choice of antibiotics, as they may have low diffusion in tissues when administered intravenously, but are effective when administered locally.

View Article and Find Full Text PDF

sarcoma is rare and its clinical features remain unclear. Given the similarity in presentation, it is possible that previously reported cases of Ewing-like adamantinoma may have been sarcoma. The present case report describes a tumor in a 55-year-old man that was originally thought to be a Ewing-like adamantinoma, but was recently found to be an sarcoma following direct sequencing.

View Article and Find Full Text PDF

Rotator Cuff Repair Study Designs Correlate With Revision Shoulder Surgery Rates: A Systematic Review.

Arthrosc Sports Med Rehabil

December 2024

Department of Orthopedics, Division of Sports Medicine and Shoulder Surgery, University of Colorado School of Medicine, Aurora, Colorado, U.S.A.

Purpose: To identify arthroscopic rotator cuff repair study groups and evaluate if study design or other study characteristics correlate with a repeat ipsilateral shoulder surgery.

Methods: A systematic search of the PubMed, Embase, and Cochrane Library databases was conducted on March 20, 2021, and April 2, 2021. The following search terms were used by 2 different researchers: ((Rotator cuff repair[Title/Abstract]) AND (Revision[Title/Abstract]) NOT (Systematic Review[Title/Abstract]) NOT (arthroplasty[Title/Abstract]).

View Article and Find Full Text PDF

Purpose: To compare the biomechanics of a drop vertical jump (DVJ) landing task and functional outcomes among patients with anterior cruciate ligament reconstruction (ACLR) with quadriceps tendon (QT) and patellar tendon (PT) autografts.

Methods: Physically active patients who underwent primary ACLR with either a QT or PT autograft were included in this study. All were within 6 months to 2 years after surgery and cleared for return to physical activity.

View Article and Find Full Text PDF

Purpose: To determine the patient demographics and incidence of hip arthroscopy after total hip arthroplasty using the PearlDiver database.

Methods: This is a retrospective study of patients undergoing total hip arthroplasty and arthroscopic hip surgery. The PearlDiver Claims Database was queried using Current Procedural Terminology (CPT) codes for records from 2010 to 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!