A Comprehensive Study of Internal Distraction Plating, an Alternative Method for Distal Radius Fractures.

J Clin Diagn Res

Senior Resident and Lecturer, Department of Orthodontics, Maratha Mandal Institute, Belgaum, Karnataka, India .

Published: December 2016

Introduction: The management of highly comminuted distal radius fractures still remains a major treatment challenge. Articular comminution and compromised bone quality are the culprits. One novel approach is the technique of Internal Distraction Plating which involves "bridging" the fracture with the use of a standard 3.5mm plate applied dorsally in distraction from the radius, proximal to the fracture, to the long finger metacarpal distally, bypassing the comminuted segment. The plate is removed once fracture union has been achieved.

Aim: The present study was conducted with the aim to evaluate the role of internal dorsal distraction plating as an alternative method in the treatment of fracture distal radius in terms of special indications, technique and outcome.

Materials And Methods: This study was a prospective longitudinal study on 20 patients (mean age 62 years) treated with internal distraction plating for comminuted distal radius fractures with specific indications. Regular follow-ups with standard radiographs and analysis were done upto 24 months. Functional outcome were assessed by DASH Score and the Gartland and Werley demerit score.

Results: At final follow-up, all fractures had united and X-rays showed mean palmar tilt of 7°, positive ulnar variance of 0.5mm, radial inclination of 18° and average loss of 2mm of radial height. Mean range of motion values for wrist flexion 46°, extension 50°, pronation 79° and supination 77° At final follow-up, the mean DASH score was 32. 85% patient had excellent to good result as per Gartland and Werley demerit score. This construct has yield satisfactory clinical and radiographic results with these very challenging injuries.

Conclusion: The purpose of this study was to report the radiographic and the functional outcomes of treatment with this technique. External fixator and volar plating in communited distal end radius fractures are not always satisfactory in old age with osteoporotic bone because of complications associated with them. The current technique represents an alternative that provides union of the comminuted distal radius fracture with anatomical alignment, optimal range of motion and with minimal clinical disability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5296529PMC
http://dx.doi.org/10.7860/JCDR/2016/21926.9036DOI Listing

Publication Analysis

Top Keywords

distal radius
24
distraction plating
16
radius fractures
16
internal distraction
12
comminuted distal
12
plating alternative
8
alternative method
8
dash score
8
gartland werley
8
werley demerit
8

Similar Publications

Objective: Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.

Methods: Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old.

View Article and Find Full Text PDF

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.

View Article and Find Full Text PDF

Objective: To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.

Methods: Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers.

View Article and Find Full Text PDF

Objective: To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.

Methods: Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.

View Article and Find Full Text PDF

Objective: To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.

Methods: Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!