Background: Detections of influenza A subtype-specific antibody responses are often complicated by the presence of cross-reactive antibodies. We developed two novel multiplex platforms for antibody detection. The multiplexed magnetic fluorescence microsphere immunoassay (MAGPIX) is a high-throughput laboratory-based assay. Chembio Dual Path Platform (DPP) is a portable and rapid test that could be used in the field.

Methods: Twelve recombinant globular head domain hemagglutinin (GH HA1) antigens from A(H1N1)pdm09 (pH1N1), A(H2N2), A(H3N2), A(H5N1), A(H7N9), A(H9N2), A(H13N9), B/Victoria lineage, B/Yamagata lineage viruses, and protein A control were used. Human sera from U.S. residents either vaccinated (with H5N1 or pH1N1) or infected with pH1N1 influenza viruses and sera from live bird market workers in Bangladesh (BDPW) were evaluated. GH HA1 antigens and serum adsorption using full ectodomain recombinant hemagglutinins from A(pH1N1) and A(H3N2) were introduced into the platforms to reduce cross-reactivity.

Results: Serum adsorption reduced cross-reactivity to novel subtype HAs. Compared to traditional hemagglutination inhibition or microneutralization assays, when serum adsorption and the highest fold rise in signals were used to determine positivity, the correct subtype-specific responses were identified in 86%-100% of U.S. residents exposed to influenza antigens through vaccination or infection (N=49). For detection of H5N1-specific antibodies in sera collected from BDPW, H5 sensitivity was 100% (six of six) for MAGPIX, 83% (five of six) for DPP, H5 specificity was 100% (15/15), and cross-reactivity against other subtype was 0% (zero of six) for both platforms.

Conclusion: MAGPIX and DPP platforms can be utilized for high-throughput and in-field detection of novel influenza virus infections.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5410722PMC
http://dx.doi.org/10.1111/irv.12449DOI Listing

Publication Analysis

Top Keywords

serum adsorption
12
novel multiplex
8
subtype-specific antibody
8
antibody responses
8
high-throughput in-field
8
ha1 antigens
8
influenza
5
novel
4
multiplex assay
4
platforms
4

Similar Publications

Biomarkers.

Alzheimers Dement

December 2024

5M Biomed, LLC, Atlanta, GA, USA.

Background: Enriching and detecting Alzheimer's disease (AD) biomarkers in cerebral spinal fluid (CSF) or blood samples are increasingly applied in the AD diagnosis and monitoring of disease progression and treatment response. The accuracy of these processes is dependent on the sensitivity and specificity of capturing and quantifying AD biomarkers, e.g.

View Article and Find Full Text PDF

Quaternized Nanofiber-Based Anion-Exchange Chromatography Membrane with Periodic Diagonal Surface Structure for Efficient Protein Separation.

ACS Appl Mater Interfaces

January 2025

Key Laboratory of Textile Fiber and Products, Ministry of Education, Hubei International Scientific and Technological Cooperation Base of Intelligent Textile Materials & Application, Wuhan Textile University, Wuhan 430200, China.

Constructing a nanofibrous membrane with high flow rate surface pore structure and high-density ligand chemical structure is a promising strategy to balance the trade-off between high flow rates and high adsorption capacity for protein separation and purification. Herein, a nanofiber-based ion-exchange chromatography membrane with a periodic diagonal surface structure and high ionic strength ligands was fabricated using dispersion cross-linking, wet coating, and template printing with a three-wire diagonal woven mesh. For this membrane, EVOH nanofibers were used as skeleton, glutaraldehyde (GA) as cross-linking agent, and quaternized chitosan (QCS) as binder and functional ligand.

View Article and Find Full Text PDF

Stable Antifouling and Antibacterial Coating Based on Assembly of Copper-Phenolic Networks.

ACS Appl Bio Mater

January 2025

Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9, Canada.

Biofilm formation on medical devices has become a worldwide issue arising from its resistance to bactericidal agents and presenting challenges to eradicating biofouling adhesion, especially in biological fluids. Metal-phenolic networks have been demonstrated as a versatile and efficient strategy to prevent biofilm formation by endowing medical devices with prolonged antifouling and antibacterial activities in a one-step surface modification. In this study, we report a simple and environmentally friendly method using coordination chemistry between copper ions (Cu) and dopamine-containing copolymer to fabricate metal-phenolic network-based coatings.

View Article and Find Full Text PDF

Impact of Glycosylation of Apolipoprotein D on Its Interaction with Gold Nanoparticles: Insights from Molecular Dynamics Simulations.

ACS Appl Mater Interfaces

January 2025

Center for Soft Condensed Matter Physics and Interdisciplinary Research, School of Physical Science and Technology, Soochow University, Suzhou 215006, China.

Efficient delivery of nanoparticles (NPs) as carriers for biochemical substances is crucial in various biomedical applications. In this study, we systematically investigate the interactions between glycosylated and nonglycosylated forms of Apolipoprotein D (ApoD) with gold nanoparticles (AuNPs) functionalized with different polymer coatings, including polyethylene glycol (PEG) and zwitterionic polymers. Using all-atom molecular dynamics simulations, we demonstrate that glycosylation significantly enhances the adsorption behavior of ApoD on AuNP surfaces, with the extent of this enhancement being dependent on the type (especially the charge property) of the polymer coatings.

View Article and Find Full Text PDF

Experimental reproducibility in organ-on-chip (OOC) devices is a challenging issue, mainly caused by cell adhesion problems, as OOC devices are made of bioinert materials not suitable for natural cellularization of their surfaces. To improve cell adhesion, several surface functionalization techniques have been proposed, among which the simple use of an intermediate layer of adsorbed proteins has become the preferred one by OOC users. This way, the cells use surface receptors to adhere to the adsorbed proteins, which are in turn attached to the surface.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?