Effects of Upgrade Versus De Novo Cardiac Resynchronization Therapy on Clinical Response and Long-Term Survival: Results from a Multicenter Study.

Circ Arrhythm Electrophysiol

From the Department of Cardiology, J.W. Goethe University, Frankfurt, Germany (M.V., J.W.E., S.P.L., S.H.H.); Department of Cardiology, Medical Centre, Hungarian Defence Forces, Budapest, Hungary (Z.B., D.V., G.Z.D.); and Department of Cardiology, Evangelical Hospital Bielefeld, Germany (T.B., C.W.I.).

Published: February 2017

Background: Benefits of cardiac resynchronization therapy (CRT) on morbidity and mortality in selected patients are well known. Although the number of upgrade procedures from single- or dual-chamber devices to CRT is increasing, there are only sparse data on the outcomes of upgrade procedures compared with de novo CRT. This study aimed to evaluate clinical response and survival in patients receiving de novo versus upgrade CRT defibrillator therapy.

Methods And Results: Prospectively collected outcome data were compared in patients undergoing de novo or upgrade CRT defibrillator implantation at 3 implant centers in Germany and Hungary. Clinical response was defined as an improvement by at least one New York Heart Association (NYHA) functional class. CRT implantation was performed in 552 consecutive patients of whom 375 underwent a de novo and 177 an upgrade procedure. Upgrade patients were more often implanted for secondary prevention, suffered more often from atrial fibrillation, chronic kidney disease, diabetes mellitus, and dyslipidemia, and had more often a non-LBBB (left bundle branch block) wide QRS complex, and lower left ventricular ejection fraction. Upgrade procedures were associated with a lower response rate compared to the de novo group (57% versus 69%, univariate=0.008, multivariate=0.021). During the follow-up of 37±28 months, survival was worse after upgrade compared with de novo CRT defibrillator implantations (hazard ratio, 1.65; 95% confidence interval, 1.22-2.24; =0.001) even after careful adjustment for important baseline variables (adjusted hazard ratio, 1.68; 95% confidence interval, 1.20-2.34; =0.002) and after propensity-score matching (propensity-adjusted hazard ratio, 1.79; 95% confidence interval, 1.08-2.95; =0.023).

Conclusions: Both clinical response and long-term survival were less favorable in patients undergoing CRT upgrade compared to de novo implantations.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.116.004471DOI Listing

Publication Analysis

Top Keywords

clinical response
16
compared novo
16
upgrade procedures
12
crt defibrillator
12
hazard ratio
12
95% confidence
12
confidence interval
12
upgrade
9
novo
8
cardiac resynchronization
8

Similar Publications

Current literature is unclear on the safety and optimal timing of delivery for pregnant individuals with gestational diabetes mellitus, which inspired our study team to conduct a web-based survey study exploring patient and provider opinions on delivery options. However, an incident of fraudulent activity with survey responses prompted a shift in the focus of the research project. Unfortunately, despite the significant rise of web-based surveys used in medical research, there remains very limited evidence on the implications of and optimal methods to handle fraudulent web-based survey responses.

View Article and Find Full Text PDF

To provide proof-of-concept (PoC), dose-range finding, and safety data for BI 1358894, a TRPC4/5 ion channel inhibitor, in patients with borderline personality disorder (BPD). This was a phase 2, multinational, randomized, double-blind, placebo controlled trial. Patients were randomized to oral placebo or BI 1358894 (5 mg, 25 mg, 75 mg, or 125 mg) once daily in a 2.

View Article and Find Full Text PDF

Communicating hydrocephalus following stereotactic radiosurgery for periventricular meningiomas: illustrative cases.

J Neurosurg Case Lessons

January 2025

Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, University College London Hospitals, London, United Kingdom.

Background: Stereotactic radiosurgery (SRS) is a well-established option for the management of intracranial tumors, including meningiomas. Although valued for its low invasiveness and precision, it still carries a risk of complications. Communicating hydrocephalus is a serious, albeit rarely reported, complication of SRS.

View Article and Find Full Text PDF

WHO's 2013 PMTCT guidelines recommended lifelong antiretroviral therapy (ART) for HIV-infected pregnant and breastfeeding women, exclusive breastfeeding (EBF), nevirapine prophylaxis (NVP) and early infant diagnosis (EID) for HIV-exposed-breastfed infants. We examined the association between knowledge and adherence to these guidelines among 550 HIV-infected pregnant women in Maharashtra, India. Knowledge of PMTCT guidelines was assessed using a structured-questionnaire during enrollment.

View Article and Find Full Text PDF

Objective: To assess the efficacy and safety of cefiderocol (CFDC) in the treatment of Gram-negative bacteria (GNB) infections.

Methods: Relevant studies were collected from PubMed, Web of Science, Cochrane, and Embase databases, from inception to 15 October 2023. The search formula was as follow: "cefiderocol", "S-649266", "Gram-Negative Bacteria", "Gram Negative Bacteria", "Klebsiella pneumoniae", "Hyalococcus pneumoniae", and "Bacterium pneumoniae proposal".

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?