Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To assess the ANB angle's and Wits appraisal's diagnostic performance using an extended version of Receiver Operating Curve (ROC) analysis, which renders ROC surfaces. These were calculated for both the conventional and normalized cephalometric tests (calculated by exchanging the patient's reference landmarks with those of the Procrustes superimposed sample mean shape).The required 'gold standard' was derived statistically, by applying generalized Procrustes superimposition (GPS) and principal component analysis (PCA) to the digitized landmarks, and ordering patients based upon their PC2 scores.
Methods: Digitized landmarks of 200 lateral cephalograms (107 males, mean age: 12.8 years, SD: 2.2, 93 females, mean age: 13.2 years, SD: 1.7) were subjected to GPS and PCA. Upon calculating the conventional and normalized ANB and Wits values, ROC surfaces were constructed by varying not just the cephalometric test's cut-off value within each ROC curve, but also the gold standard cut-off value over different ROC curves in 220 steps between -2 and 2 standard deviations along PC2. The volume under the resulting ROC surfaces (VUS) served as a measure of overall diagnostic performance. The statistical significance of the volume differences was determined using permutation tests (1000 rounds, with replacement).
Results: The diagnostic performance of the conventional ANB and Wits was remarkably similar for both Class I/II (81.1 and 80.75% VUS, respectively, P > 0.05). Normalizing the measurements improved all VUS highly significantly (91 and 87.2 per cent, respectively, P < 0.001).
Conclusion: The conventional ANB and Wits do not differ in their diagnostic performance. Normalizing the measurements does seem to have some merit.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejo/cjx002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!