The repetition rate of a Kerr comb composed of a single soliton in an anomalous group velocity dispersion silicon-nitride microcavity is measured as a function of pump frequency. By comparing operation in the soliton and non-soliton states, the contributions from the Raman soliton self-frequency shift (SSFS) and the thermal effects are evaluated; the SSFS is found to dominate the changes in the repetition rate, similar to silica cavities. The relationship between the changes in the repetition rate and the pump frequency detuning is found to be independent of the nonlinearity coefficient and dispersion of the cavity. Modeling of the repetition rate change by using the generalized Lugiato-Lefever equation is discussed; the Kerr shock is found to have only a minor effect on repetition rate for cavity solitons with duration down to ∼50  fs.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.42.000759DOI Listing

Publication Analysis

Top Keywords

repetition rate
24
pump frequency
8
changes repetition
8
rate
6
repetition
5
soliton
4
soliton repetition
4
rate silicon-nitride
4
silicon-nitride microresonator
4
microresonator repetition
4

Similar Publications

Aims: We aimed to establish one-minute sit-to-stand test (1-min STST) cut-off values that align with the guideline-recommended six-minute walk test (6MWT) thresholds (165m and 440m) for one-year mortality risk stratification in pulmonary hypertension (PH) patients. Furthermore, we aimed to compare clinical characteristics and long-term mortality among patients stratified by these proposed 1-min STST cut-offs.

Methods: All patients performed the 1-min STST and 6MWT.

View Article and Find Full Text PDF

Laser-plasma acceleration of protons offers a compact, ultra-fast alternative to conventional acceleration techniques, and is being widely pursued for potential applications in medicine, industry and fundamental science. Creating a stable, collimated beam of protons at high repetition rates presents a key challenge. Here, we demonstrate the generation of multi-MeV proton beams from a fast-replenishing ambient-temperature liquid sheet.

View Article and Find Full Text PDF

This study analyzed the acute and time-course changes following one resistance training (RT) set (1SET) and three sets (3SET) on hemodynamic and physical performance parameters in individuals with different cognitive impairment levels. Thirty-nine individuals (22 women and 17 men aged 80 ± 9 years) grouped by cognitive impairment (mild [MILD], moderate [MOD], and severe [SEV]) randomly performed two protocols, each separated by one week, of 1SET or 3SET of 10 repetitions. Before (PRE), immediately (POST), and 72 h after (POST72) protocols, the participants performed the following measurements: systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), 1-kg medicine ball throw (MBT) distance, five-repetition sit-to-stand (STS) time, and handgrip strength (HGS).

View Article and Find Full Text PDF

Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.

View Article and Find Full Text PDF

Background: Objective training load (TL) indexes used in resistance training lack physiological significance. This study was aimed to provide a muscle physiology-based approach for quantifying TL in resistance exercises (REs).

Methods: Following individual torque-velocity profiling, fifteen participants (11 healthy males, stature: 178.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!