Fast and stable repair of segmental bone defects remains a challenge for clinical orthopedic surgery. In recent years, porous tantalum has been widely applied in clinical orthopedics for low modulus of elasticity, with three-dimensional microstructures similar to cancellous bone and excellent biocompatibility. To further improve bone the repairing ability of porous tantalum, the cyclo(-RGDfK-) peptide was coated on the surface of porous tantalum scaffolds. A model of 15 mm segmental defect was made at the midshaft of right radius in New Zealand White rabbits. In the experimental group, defects were implanted (press-fit) using porous tantalum scaffolds modified with cyclo(-RGDfK-) peptide. Control animals were implanted with non-modified porous tantalum scaffolds or xenogeneic cancellous bone scaffolds, respectively. No implant was provided for the blank group. Bone repair was assessed by X-ray and histological observations at 4, 8, and 16 weeks post-operation, with biomechanical tests and micro-computed tomography performed at 16 weeks post-surgery. The results showed that bone formation was increased at the interface and inside the inner pores of modified porous tantalum scaffolds than those of non-modified porous tantalum scaffolds; biomechanical properties in the modified porous tantalum group were superior to those of the non-modified porous tantalum and xenogeneic cancellous bone groups, while new bone volume fractions using micro-computed tomography analysis were similar between the modified porous tantalum and xenogeneic cancellous bone groups. Our findings suggested that modified porous tantalum scaffolds had enhanced repairing ability in segmental bone defect in rabbit radius, and may serve as a potential material for repairing large bone defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10856-017-5860-4 | DOI Listing |
J Orthop Surg Res
December 2024
Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.
Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).
Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.
Langmuir
December 2024
Key Laboratory of Soft Chemistry and Functional Materials of Education Ministry, Nanjing University of Science and Technology, Nanjing 210094, China.
Traditional anodization was generally conducted in aqueous or water-containing solutions at room temperature or even lower temperatures. The two best known examples of the application of traditional anodization in the fabrication of nanostructured oxides are porous anodic alumina and titania nanotube films. In 1998, Melody et al.
View Article and Find Full Text PDFZhongguo Gu Shang
November 2024
Department of Joint Surgery, the 940th Hospital of PLA Joint Logistics Support Force, Lanzhou 730050, Gansu, China.
Objective: To explore the surgical technique and clinical outcomes of biological total hip arthroplasty(THA) combined with impacting bone grafting for the treatment of moderate to severe acetabular invagination secondary to rheumatoid arthritis(RA).
Methods: Total of 20 patients(28 hips) with RA secondary to acetabular invagination were treated with THA of bioprosthesis combined with autogenous bone grafting from January 2012 to October 2020, including 5 males(8 hips) and 15 females(20 hips) with an average age of (55.10±4.
BMC Musculoskelet Disord
November 2024
Center for Sports Medicine, Southwest Hospital, Third Military Medical University, No. 30 Gaotanyan Street, Shapingba District, Chongqing, 400036, China.
Purpose: The conversion of knee arthrodesis to total knee arthroplasty (TKA) is a challenging procedure. This article aims to report a case of fusion knee with patellar absence who was converted to TKA and has achieved good results.
Methods: The patient, a 23 years old Tibetan Buddhist monk, sustained a left knee joint injury at the age of 12 due to a car accident, leading to subsequent knee arthrodesis at 18 years old as a result of recurrent severe infections.
J Arthroplasty
November 2024
Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; University of Nottingham, Nottingham, United Kingdom.
Background: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components.
Methods: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components.