A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Characteristics of successful filtering blebs at 1 year after trabeculectomy using swept-source three-dimensional anterior segment optical coherence tomography. | LitMetric

Purpose: To identify the cross-sectional characteristics of filtering blebs associated with intraocular pressure (IOP) control at 1 year after trabeculectomy with a square scleral flap and a fornix-based conjunctival flap.

Methods: A retrospective consecutive case series study was conducted. Eighty-four eyes of 79 patients who had undergone primary trabeculectomy were included. Surgical success was defined as IOP ≤15 mmHg and a >20% reduction in IOP without glaucoma medication and without additional glaucoma surgery at 1 year after trabeculectomy. The subjects were classified into two groups according to whether surgery was successful or unsuccessful. Filtering blebs were examined using swept-source three-dimensional anterior segment optical coherence tomography and evaluated for the following quantitative parameters: maximum bleb height, maximum bleb wall thickness, and ratio of hypo-reflective space of the bleb wall.

Results: Sixty-six eyes were determined to be successful and 18 eyes unsuccessful. Univariate analysis showed significant differences between the two groups regarding bleb height (P < 0.001), bleb wall thickness (P = 0.011), and ratio of hypo-reflective space of the bleb wall (P = 0.002). Multivariate logistic regression analysis confirmed that the bleb height was significantly associated with success in trabeculectomy [odds ratio 13.996 (95% confidence interval 1.184-165.420); P = 0.036].

Conclusion: A tall bleb with a thick hypo-reflective wall may be a feature of the well-functioning bleb.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-017-0504-2DOI Listing

Publication Analysis

Top Keywords

filtering blebs
12
1 year trabeculectomy
12
swept-source three-dimensional
8
three-dimensional anterior
8
anterior segment
8
segment optical
8
optical coherence
8
coherence tomography
8
maximum bleb
8
bleb height
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!