Vacuolar ion channels in the liverwort Marchantia polymorpha: influence of ion channel inhibitors.

Planta

Department of Biophysics, Institute of Biology and Biochemistry, Maria Curie-Skłodowska University, Akademicka 19, 20-033, Lublin, Poland.

Published: May 2017

Potassium-permeable slow activating vacuolar channels (SV) and chloride-permeable channels in the vacuole of the liverwort Marchantia polymorpha were characterized in respect to calcium dependence, selectivity, and pharmacology. The patch-clamp method was used in the study of ion channel activity in the vacuoles from the liverwort Marchantia polymorpha. The whole-vacuole recordings allowed simultaneous observation of two types of currents-predominant slow activated currents recorded at positive voltages and fast activated currents recorded at negative voltages. Single-channel recordings carried out in the gradient of KCl indicated that slow activated currents were carried by potassium-permeable slowly activating vacuolar channels (SV) and fast activated currents-by chloride-permeable channels. Both types of the channels were dependent in an opposite way on calcium, since elimination of this ion from the cytoplasmic side caused inhibition of SV channels, but the open probability of chloride-permeable channels even increased. The dependence of the activity of both channels on different types of ion channel inhibitors was studied. SV channels exhibited different sensitivity to potassium channel inhibitors. These channels were insensitive to 3 mM Ba, but were blocked by 3 mM tetraethyl ammonium (TEA). Moreover, the activity of the channels was modified in a different way by calcium channel inhibitors. 200 µM Gd was an effective blocker, but 50 µM ruthenium red evoked bursts of the channel activity resulting in an increase in the open probability. Different effectiveness of anion channel inhibitors was observed in chloride-permeable channels. After the application of 100 µM Zn, a decrease in the open probability was recorded but the channels were still active. 50 µM DIDS was more effective, as it completely blocked the channels.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5391376PMC
http://dx.doi.org/10.1007/s00425-017-2661-4DOI Listing

Publication Analysis

Top Keywords

channel inhibitors
20
chloride-permeable channels
16
channels
15
liverwort marchantia
12
marchantia polymorpha
12
ion channel
12
activated currents
12
open probability
12
activating vacuolar
8
vacuolar channels
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!