Safety and efficacy of embolization using Onyx of persistent type II endoleaks after abdominal endovascular aneurysm repair.

Diagn Interv Imaging

Department of radiology, hôpital Pellegrin, place Amélie-Raba-Léon, 33076 Bordeaux, France.

Published: June 2017

Purpose: To retrospectively evaluate the safety and efficacy of embolization of persistent type II endoleaks occurring after abdominal endovascular aneurysm repair (EVAR) using ethylene vinyl alcohol copolymer (Onyx).

Material And Methods: Between 2008 and 2016, 28 consecutives patients (25 men, 3 women) with a mean age of 75.3years±9 (SD) (range: 59-90years) were treated for 29 persistent type II endoleaks with increasing aneurysm size>5mm occurring after EVAR. A total of 35 embolization procedures were performed using Onyx, via a transarterial route (n=25) or direct puncture (n=10), with or without additional metallic coils. The endpoints were to evaluate the clinical efficacy, corresponding to the stabilization or decrease of aneurism size, and the technical efficacy, corresponding to the ability to complete the embolization.

Results: No severe complications were observed during and after embolization. The primary and secondary clinical efficacies were 75% (21/28) and 96.4% (27/28), respectively. Overall primary technical efficacy rate was 58.6% (17/29), greater for transarterial technique (72.8%) than for direct puncture (14.3%) (P=0.01). Secondary technical efficacy was 72.4% (21/29), with no differences between transarterial (81.8%) and direct puncture (42.8%) (P=0.06).

Conclusion: Embolization with Onyx of type II endoleaks after EVAR appears a safe and effective procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diii.2017.01.003DOI Listing

Publication Analysis

Top Keywords

type endoleaks
16
persistent type
12
direct puncture
12
technical efficacy
12
safety efficacy
8
efficacy embolization
8
embolization onyx
8
abdominal endovascular
8
endovascular aneurysm
8
aneurysm repair
8

Similar Publications

Thoracic endovascular aortic repair (TEVAR) is widespread. We report a case of graft migration and dissecting aneurysm rupture after trauma. An 82-year-old man with a history of TEVARs for chronic type B aortic dissection had sudden dyspnea and hemoptysis after falling from a stationary bicycle.

View Article and Find Full Text PDF

Background: Endovascular abdominal aneurysm repair (EVAR) offers a less invasive approach to treating abdominal aortic aneurysms (AAA) compared to open repair. However, EVAR is associated with higher rates of reintervention. This study investigates the early and mid-term outcomes of patients who underwent late open conversion including aneurysmorrhaphy after EVAR at our institution.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the safety and effectiveness of the Zenith Dissection Endovascular System (ZDES) against traditional stent grafts for repairing acute complicated Type B Aortic Dissection (AcTBAD).
  • A retrospective analysis of 32 patients revealed that the ZDES group experienced fewer postoperative adverse events (12 vs. 37), demonstrating better outcomes in false lumen thrombosis at 6 months and lower 3-year mortality rates.
  • Despite some patients needing secondary interventions in the ZDES cohort due to aortic growth, overall results suggest the ZDES may offer improved safety and efficacy compared to traditional methods.
View Article and Find Full Text PDF

Intraoperative rescue of a dislodged renal stent during fenestrated endovascular aortic repair for treatment of type 1A endoleak.

J Vasc Surg Cases Innov Tech

February 2025

Division of Vascular and Endovascular Surgery, Cardio-Thoracic-Vascular Department, Integrated University Healthcare Giuliano-Isontina, University Hospital of Cattinara, Trieste, Italy.

In the past 15 years, fenestrated-branched endovascular aortic repair (F-BEVAR) has progressively become the first-line option for management of most complex abdominal aortic aneurysms (AAAs); with increasing experience, as well as persistent technological refinements, F-BEVAR indications have been expanded to include rescue of failures after prior EVAR. Despite the feasibility and effectiveness, F-BEVAR procedures in the presence of prior infrarenal endografts may come with higher technical complexity that should be properly anticipated, and several anatomical challenges can be expected. Among these, presence of suprarenal bare stents from prior EVAR device are certainly a frequent scenario and may sometimes make target vessel cannulation more difficult because of encroachment on the target vessel origins.

View Article and Find Full Text PDF

Objectives: Embolizing an abdominal aortic aneurysm sac through a transcaval approach is a novel approach to treat type-II endoleaks that occur following aortic endografting. This study reviews the outcomes of this treatment in one of the few centres in Australia that offers this procedure.

Methods: A retrospective cohort study was conducted, including patients who had received transcaval embolisation of type-II endoleak over a 9-year period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!