Assessment of myocardial injury after reperfused infarction by T1ρ cardiovascular magnetic resonance.

J Cardiovasc Magn Reson

Department of Radiology, Perelman School of Medicine, University of Pennsylvania, 1 Silverstein 3400 Spruce Street, Philadelphia, PA, 19104, USA.

Published: February 2017

Background: The evolution of T1ρ and of other endogenous contrast methods (T2, T1) in the first month after reperfused myocardial infarction (MI) is uncertain. We conducted a study of reperfused MI in pigs to serially monitor T1ρ, T2 and T1 relaxation, scar size and transmurality at 1 and 4 weeks post-MI.

Methods: Ten Yorkshire swine underwent 90 min of occlusion of the circumflex artery and reperfusion. T1ρ, T2 and native T1 maps and late gadolinium enhanced (LGE) cardiovascular magnetic resonance (CMR) data were collected at 1 week (n = 10) and 4 weeks (n = 5). Semi-automatic FWHM (full width half maximum) thresholding was used to assess scar size and transmurality and compared to histology. Relaxation times and contrast-to-noise ratio were compared in healthy and remote myocardium at 1 and 4 weeks. Linear regression and Bland-Altman was performed to compare infarct size and transmurality.

Results: Relaxation time differences between infarcted and remote myocardial tissue were ∆T1 (infarct-remote) = 421.3 ± 108.8 (1 week) and 480.0 ± 33.2 ms (4 week), ∆T1ρ = 68.1 ± 11.6 and 74.3 ± 14.2, and ∆T2 = 51.0 ± 10.1 and 59.2 ± 11.4 ms. Contrast-to-noise ratio was CNR = 7.0 ± 3.5 (1 week) and 6.9 ± 2.4 (4 week), CNR = 12.0 ± 6.2 and 12.3 ± 3.2, and CNR = 8.0 ± 3.6 and 10.3 ± 5.8. Infarct size was not significantly different for T1ρ, T1 and T2 compared to LGE (p = 0.14) and significantly decreased from 1 to 4 weeks (p < 0.01). Individual infarct size changes were ∆T1ρ = -3.8%, ∆T1 = -3.5% and ∆LGE = -2.8% from 1 - 4 weeks, but there was no observed change in infarct size for T2 or histologically.

Conclusions: T1ρ was highly correlated with alterations left ventricle (LV) pathology at 1 and 4 weeks post-MI and therefore it may be a useful method endogenous contrast imaging of infarction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5310026PMC
http://dx.doi.org/10.1186/s12968-017-0332-zDOI Listing

Publication Analysis

Top Keywords

cardiovascular magnetic
8
magnetic resonance
8
scar size
8
size transmurality
8
contrast-to-noise ratio
8
infarct size
8
t1ρ
5
assessment myocardial
4
myocardial injury
4
injury reperfused
4

Similar Publications

Purpose: To describe a case of short common trunk of the occipital artery (OA) and ascending pharyngeal artery (APA) arising from the internal carotid artery (ICA).

Methods: A 36-year-old woman with a history of surgical resection of a right lateral ventricular meningioma and atheromatous plaque of the right ICA underwent cranial magnetic resonance (MR) imaging and MR angiography of the head and neck region with a 3-Tesla scanner.

Results: MR angiography of the neck region showed a small atheromatous plaque at the origin of the right ICA and an anomalous artery arising from the posteromedial aspect of the right ICA at the distal end of the carotid bulb.

View Article and Find Full Text PDF

Use of AI in Cardiac CT and MRI: A Scientific Statement from the ESCR, EuSoMII, NASCI, SCCT, SCMR, SIIM, and RSNA.

Radiology

January 2025

From the Department of Radiology, University of Washington, UW Medical Center-Montlake, Seattle, Wash (D.M.); Department of Radiology, OncoRad/Tumor Imaging Metrics Core (TIMC), University of Washington, Seattle, Wash (D.M.); Department of Radiology and Imaging Sciences, Emory University, Atlanta, Ga (M.v.A.); Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, the Netherlands (M.H.); Department of Radiology, Mayo Clinic, Rochester, Minn (T.L., E.E.W.); Departments of Cardiology and Radiology, Royal Brompton Hospital, London, United Kingdom (E.D.N.); School of Biomedical Engineering and Imaging Sciences, King's College, London, United Kingdom (E.D.N.); Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (B.D.A.); Department of Radiology, University of Cagliari, Cagliari, Italy (L.S.); Department of Radiology, University of Groningen, University Medical Center Groningen, Hanzeplein 1 Postbus 30 001, 9700 RB Groningen, the Netherlands (R.V.); Department of Medical Imaging, University Medical Imaging Toronto, University of Toronto, Toronto, Ontario, Canada (K.H.); and Toronto General Hospital Research Institute, University Health Network, University of Toronto, Toronto, Ontario, Canada (K.H.).

Artificial intelligence (AI) offers promising solutions for many steps of the cardiac imaging workflow, from patient and test selection through image acquisition, reconstruction, and interpretation, extending to prognostication and reporting. Despite the development of many cardiac imaging AI algorithms, AI tools are at various stages of development and face challenges for clinical implementation. This scientific statement, endorsed by several societies in the field, provides an overview of the current landscape and challenges of AI applications in cardiac CT and MRI.

View Article and Find Full Text PDF

Hyperpolarized Xe MRI/MRS enables quantitative mapping of function in lung airspaces, membrane tissue, and red blood cells (RBCs) within the pulmonary capillaries. The RBC signal also exhibits cardiogenic oscillations that are reduced in pre-capillary pulmonary hypertension (PH). This effect is obscured in patients with concomitant defects in transfer from airspaces to RBCs, which increase RBC oscillation amplitudes.

View Article and Find Full Text PDF

Background: Technological advancements in artificial intelligence (AI) are redefining cardiac imaging by providing advanced tools for analyzing complex health data. AI is increasingly applied across various imaging modalities, including echocardiography, magnetic resonance imaging (MRI), computed tomography (CT), and nuclear imaging, to enhance diagnostic workflows and improve patient outcomes.

Hypothesis: Integrating AI into cardiac imaging enhances image quality, accelerates processing times, and improves diagnostic accuracy, enabling timely and personalized interventions that lead to better health outcomes.

View Article and Find Full Text PDF

Contrast media are essential agents that enhance the diagnostic capabilities of imaging studies, such as computed tomography and magnetic resonance imaging. However, concerns regarding the risk of adverse events have led to cautious use in patients with chronic kidney disease. A multidisciplinary review by nephrologists, cardiologists, and radiologists at National Taiwan University Hospital examined evidence linking iodinated contrast media and gadolinium-based contrast agents with acute kidney injury and nephrogenic systemic fibrosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!