Purpose: To determine if radiation treatment plans created based on autosegmented (AS) regions-of-interest (ROI)s are clinically equivalent to plans created based on manually segmented ROIs, where equivalence is evaluated using probabilistic dosimetric metrics and probabilistic biological endpoints for prostate IMRT.
Method And Materials: Manually drawn contours and autosegmented ROIs were created for 167 CT image sets acquired from 19 prostate patients. Autosegmentation was performed utilizing Pinnacle's Smart Probabilistic Image Contouring Engine. For each CT set, 78 Gy/39 fraction 7-beam IMRT treatment plans with 1 cm CTV-to-PTV margins were created for each of the three contour scenarios; P using manually delineated (MD) ROIs, P using autosegmented ROIs, and P using autosegmented organ-at-risks (OAR)s and the manually drawn target. For each plan, 1000 virtual treatment simulations with different systematic errors for each simulation and a different random error for each fraction were performed. The statistical probability of achieving dose-volume metrics (coverage probability (CP)), expectation values for normal tissue complication probability (NTCP), and tumor control probability (TCP) metrics for all possible cross-evaluation pairs of ROI types and planning scenarios were reported. In evaluation scenarios, the root mean square loss (RMSL) and maximum absolute loss (MAL) of coverage probability of dose-volume objectives, E[TCP], and E[NTCP] were compared with respect to the base plan created and evaluated with manually drawn contours.
Results: Femoral head dose objectives were satisfied in all situations, as well as the maximum dose objectives for all ROIs. Bladder metrics were within the clinical coverage tolerances except D for the autosegmented plan evaluated with the manual contours. Dosimetric indices for CTV and rectum could be highly compromised when the definition of the ROIs switched from manually delineated to autosegmented. Seventy-two percent of CT image sets satisfied the worst-case CP thresholds for all dosimetric objectives in all scenarios, the percentage dropped to 50% if biological indices were taken into account. Among evaluation scenarios, (MD,P ) bore the highest resemblance to (MD,P ) where 99% and 88% of cases met all CP thresholds for bladder and rectum, respectively.
Conclusions: When including daily setup variations in prostate IMRT, the dose-volume metric CP, and biological indices of ROIs were approximately equivalent for the plans created based on manually drawn targets and autosegmented OARs in 88% of cases. The accuracy of autosegmented prostates and rectums are impediment to attain statistically equivalent plans created based on manually drawn ROIs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659108 | PMC |
http://dx.doi.org/10.1002/mp.12158 | DOI Listing |
JSES Int
November 2024
Brighton and Sussex Medical School, Brighton, United Kingdom.
Background: Coronoid fracture size is one important factor in decision-making on surgical vs. nonsurgical management. There is currently no reliable, standardized technique to measure coronoid fracture size or bone loss.
View Article and Find Full Text PDFCancers (Basel)
December 2024
Laboratory of Experimental Radiotherapy, Department of Oncology, University of Leuven, 3000 Leuven, Belgium.
Background: This study aimed to explore the differences in quantitative diffusion-weighted (DW) MRI parameters in oropharyngeal squamous cell carcinoma (OPC) based on Human Papillomavirus (HPV) status before and during radiotherapy (RT).
Methods: Echo planar DW sequences acquired before and during (chemo)radiotherapy (CRT) of 178 patients with histologically proven OPC were prospectively analyzed. The volumetric region of interest (ROI) was manually drawn on the apparent diffusion coefficient (ADC) map, and 105 DW-MRI radiomic parameters were extracted.
J Stomatol Oral Maxillofac Surg
January 2025
Center for Oral and Maxillofacial Surgery, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Steiner Landstraße 124, 3500 Krems an der Donau, Austria; Clinical Application of Artificial Intelligence in Dentistry (CAAID) Group, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Steiner Landstraße 124, 3500 Krems an der Donau, Austria. Electronic address:
Precise volumetric measurement of newly formed bone after maxillary sinus floor augmentation (MSFA) can help clinicians in planning for dental implants. This study aimed to introduce a novel modular framework to facilitate volumetric calculations based on manually drawn segmentations of user-defined areas of interest on cone-beam computed tomography (CBCT) images MATERIAL & METHODS: Two interconnected networks for manual segmentation of a defined volume of interest and dental implant volume calculation, respectively, were used in parallel. The volume data of dental implant manufacturers were used for reference.
View Article and Find Full Text PDFTher Adv Musculoskelet Dis
December 2024
Grupo de Patología Musculoesquelética, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria San Carlos, Madrid, Spain.
Background: Rheumatology has experienced notable changes in the last decades. New drugs, including biologic agents and Janus kinase (JAK) inhibitors, have blossomed. Concepts such as window of opportunity, arthralgia suspicious for progression, or difficult-to-treat rheumatoid arthritis (RA) have appeared; and new management approaches and strategies such as treat-to-target have become popular.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
December 2024
Department of Oral Rehabilitation, University of Otago, 310 Great King Street North, Dunedin, New Zealand.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!