Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting.

J Strength Cond Res

1University of British Columbia, Vancouver, British Columbia, Canada; 2Faculty of Medicine, Department of Experimental Medicine, University of British Columbia, Vancouver, British Columbia, Canada; 3School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada; and 4Cardiovascular Physiology & Rehabilitation Laboratory, University of British Columbia, Vancouver, British Columbia, Canada.

Published: August 2017

Perrotta, AS, Jeklin, AT, Hives, BA, Meanwell, LE, and Warburton, DER. Validity of the elite HRV smartphone application for examining heart rate variability in a field-based setting. J Strength Cond Res 31(8): 2296-2302, 2017-The introduction of smartphone applications has allowed athletes and practitioners to record and store R-R intervals on smartphones for immediate heart rate variability (HRV) analysis. This user-friendly option should be validated in the effort to provide practitioners confidence when monitoring their athletes before implementing such equipment. The objective of this investigation was to examine the relationship and validity between a vagal-related HRV index, rMSSD, when derived from a smartphone application accessible with most operating systems against a frequently used computer software program, Kubios HRV 2.2. R-R intervals were recorded immediately upon awakening over 14 consecutive days using the Elite HRV smartphone application. R-R recordings were then exported into Kubios HRV 2.2 for analysis. The relationship and levels of agreement between rMSSDln derived from Elite HRV and Kubios HRV 2.2 was examined using a Pearson product-moment correlation and a Bland-Altman Plot. An extremely large relationship was identified (r = 0.92; p < 0.0001; confidence interval [CI] 95% = 0.90-0.93). A total of 6.4% of the residuals fell outside the 1.96 ± SD (CI 95% = -12.0 to 7.0%) limits of agreement. A negative bias was observed (mean: -2.7%; CI 95% = -3.10 to -2.30%), whose CI 95% failed to fall within the line of equality. Our observations demonstrated differences between the two sources of HRV analysis. However, further research is warranted, as this smartphone HRV application may offer a reliable platform when assessing parasympathetic modulation.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000001841DOI Listing

Publication Analysis

Top Keywords

elite hrv
16
smartphone application
16
hrv smartphone
12
heart rate
12
rate variability
12
hrv analysis
12
kubios hrv
12
hrv
11
validity elite
8
application examining
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!