[This corrects the article DOI: 10.1371/journal.pone.0166767.].

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5305109PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0172378PLOS

Publication Analysis

Top Keywords

correction vmat
4
vmat verification
4
verification based
4
based monte
4
monte carlo
4
carlo log
4
log file
4
file simulation
4
simulation experimental
4
experimental feedback
4

Similar Publications

Comparison between the SGRT and the conventional setup method for patients undergoing VMAT for pelvic malignancies.

Appl Radiat Isot

January 2025

Department of Medical Physics, Medical School, University of Crete, Heraklion, Greece. Electronic address:

Purpose: Surface Guided Radiation Treatment (SGRT) is a new method of positioning and monitoring patients on the linear accelerator's couch, using visual light cameras to monitor the skin's surface. The purpose of this study was to compare the SGRT with the conventional method, based on lasers and tattoos, in terms of accuracy and time expenditure, on patients with pelvic malignancies.

Materials And Methods: A group of 34 patients were enrolled in this study, 24 males who underwent radiotherapy prostate treatment and 10 females who underwent gynecological radiation therapy.

View Article and Find Full Text PDF

Introduction: This paper describes a method to improve gantry-dependent beam steering for Elekta traveling wave linear accelerators by applying the measured and filtered beam servo corrections to the existing lookup table (LUT). Beam steering has a direct influence on the treatment accuracy by affecting the beam symmetry and position. The presented method provides an improved LUT with respect to the default Elekta method to reduce treatment delivery interruptions.

View Article and Find Full Text PDF

Purpose: To investigate risk factors for esophageal fistula in esophageal squamous cell cancer (ESCC) patients who treated with volumetric modulated arc therapy (VMAT).

Patients And Methods: A retrospective analysis was performed on 171 ESCC patients treated with VMAT at Hefei Cancer Hospital, Chinese Academy of Sciences, from February 2017 to February 2021. Clinical and dosimetric parameters, including age, gender, feeding channel, tumor location, T stage, ulcerative tumor, were recorded.

View Article and Find Full Text PDF

Objective: To evaluate the intra-fraction and inter-fraction positional deviations in head and neck tumor patients undergoing intensity-modulated radiation therapy (IMRT) guided by cone-beam CT (CBCT), as well as the correction capability and stability of the HexaPOD evo RT 6D couch in addressing these deviations.

Methods: From May 2019 to April 2022, 59 consecutive patients with head and neck tumors were enrolled at the Department of Radiation Oncology, Peking University Third Hospital.Using the Elekta AXESSE image-guided stereotactic treatment system, a pre-treatment CBCT scan was performed, followed by bone window mode registration with the planning reference images.

View Article and Find Full Text PDF

Background: Quality assurance (QA) remains unstandardized for CT-guided online adaptive radiotherapy (CTgART) platforms (Ethos, Varian Medical Systems, Inc., Palo Alto, CA), as they become more clinically prevalent. A secondary dose calculation software (Mobius3D, Varian Medical Systems, Inc.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!