Radiotelemetry transmitters have become critical to studies of wildlife ecology. However, little is known about how transmitter implantation surgery affects the mobility of some species, including the timber rattlesnake, Crotalus horridus . Tracking snake movement can provide insights into the effects of transmitter implantation. During 2007-11, 71 radio transmitters were surgically implanted intracoelomically in 47 timber rattlesnakes. Over 20 of these snakes underwent surgery at least twice in 5 yr to replace old transmitters. Surgeries were performed under general anesthesia with a local nerve block at the site of implantation, 20 cm cranial to the cloaca. Snakes were also administered postsurgical meloxicam and enrofloxacin every 24 h for three doses. Two to five days after surgery, snakes were released at their original locations and radiotracked regularly during the active seasons (April-October 2007-11). Average daily movement data (distance traveled) were compiled for each snake. Snakes undergoing transmitter surgery in a given year did not differ significantly in distance traveled compared to snakes that had transmitters but did not have surgery in that year. Distance traveled for each snake did not differ before or after surgery or between weeks 1 and 2 postsurgery, indicating that the transmitter implantation did not alter snake movement.

Download full-text PDF

Source
http://dx.doi.org/10.7589/2016-08-186DOI Listing

Publication Analysis

Top Keywords

transmitter implantation
16
distance traveled
12
timber rattlesnake
8
rattlesnake crotalus
8
crotalus horridus
8
snake movement
8
surgery year
8
surgery
6
implantation
5
snakes
5

Similar Publications

Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in devices. Despite successful demonstrations of millimetric battery free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery.

View Article and Find Full Text PDF

: Remote monitoring (RM) cardiac implantable electronic devices for adults delivers improved patient outcomes. However, previously used bedside transmitters are not optimal due to deficient patient adherence. The goal of this study was to evaluate the efficacy of RM regarding the connectivity of smartphone app-based solutions, adherence to scheduled automatic follow-ups, and prevalence of alert-based events.

View Article and Find Full Text PDF

A deep brain stimulation-conditioned RF coil for 3T MRI.

Magn Reson Med

March 2025

Institute of Medical Physics and Radiation Protection, Department of Life Science Engineering, TH-Mittelhessen University of Applied Sciences, Giessen, Germany.

Purpose: To develop and test an MRI coil assembly for imaging deep brain stimulation (DBS) at 3 T with a reduced level of local specific absorption rate of RF fields near the implant.

Methods: A mechanical rotatable linearly polarized birdcage transmitter outfitted with a 32-channel receive array was constructed. The coil performance and image quality were systematically evaluated using bench-level measurements and imaging performance tests, including SNR maps, array element noise correlation, and acceleration capabilities.

View Article and Find Full Text PDF

Background: The autonomic nervous system (ANS) is affected by several factors, including major nutrients. However, their effects on the ANS remains unclear. Most studies had several limitations.

View Article and Find Full Text PDF

Identifying and characterizing spawning locations are paramount for the protection of critical fish habitats but can be challenging, particularly in remote locations. Using the underexplored oviduct-tagging technique, we aimed to identify the timing and location of spawning for wild Arctic char (Salvelinus alpinus) and lake trout (Salvelinus namaycush) in two high-Arctic lakes in Nunavut. Specifically, Innovasea V7 acoustic telemetry transmitters were inserted into the oviducts of 13 Arctic char and 4 lake trout, and the timing and location of tag expulsion were determined using a fine-scale positioning system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!