Anesthesia providers are frequently exposed to radiation during routine patient care in the operating room and remote anesthetizing locations. Eighty-two percent of anesthesiology residents (n = 57 responders) at our institution had a "high" or "very high" concern about the level of ionizing radiation exposure, and 94% indicated interest in educational materials about radiation safety. This article highlights key learning points related to basic physical principles, effects of ionizing radiation, radiation exposure measurement, occupational dose limits, considerations during pregnancy, sources of exposure, factors affecting occupational exposure such as positioning and shielding, and monitoring. The principle source of exposure is through scattered radiation as opposed to direct exposure from the X-ray beam, with the patient serving as the primary source of scatter. As a result, maximizing the distance between the provider and the patient is of great importance to minimize occupational exposure. Our dosimeter monitoring project found that anesthesiology residents (n = 41) had low overall mean measured occupational radiation exposure. The highest deep dose equivalent value for a resident was 0.50 mSv over a 3-month period, less than 10% of the International Commission on Radiological Protection occupational limit, with the eye dose equivalent being 0.52 mSv, approximately 4% of the International Commission on Radiological Protection recommended limit. Continued education and awareness of the risks of ionizing radiation and protective strategies will reduce exposure and potential for associated sequelae.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1089253217692110 | DOI Listing |
Spine (Phila Pa 1976)
January 2025
Department of Orthopedic Surgery, Hotel Dieu de France Hospital, Beirut, LEBANON.
Study Design: Meta-Analysis.
Objective: The purpose of this systematic review and meta-analysis was to pool the available data comparing MIS to open surgery for thoracolumbar fractures and provide a more comprehensive assessment on this topic.
Background: There remains a debate over whether minimally invasive surgery (MIS) or open fixation provides superior outcomes for patients with thoracolumbar fractures.
Biomater Res
January 2025
Center for Plastic & Reconstructive Surgery, Department of Dermatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, Zhejiang, China.
Cutaneous photoaging, induced by chronic exposure to ultraviolet (UV) radiation, typically manifests as alterations in both the physical appearance and functional properties of the skin and may predispose individuals to cancer development. Recent studies have demonstrated the reparative potential of exosomes derived from mesenchymal stem cells in addressing skin damage, while specific reports highlight their efficacy in ameliorating skin photoaging. However, the precise role of exosomes derived from human hair follicle mesenchymal stem cells (HFMSC-Exos) in the context of cutaneous photoaging remains largely unexplored.
View Article and Find Full Text PDFJ Soc Cardiovasc Angiogr Interv
December 2024
Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center of Utrecht, Utrecht, the Netherlands.
Background: Three-dimensional rotational angiography (3DRA) is a promising advancement to guide cardiac catheterizations. It is used with restraint in critically ill infants with congenital heart disease (CHD) due to the lack of research conducted within this patient group.
Methods: Data of all infants with CHD and a body weight <5 kg who underwent cardiac catheterization with the use of 3DRA between November 2011 and April 2021 were retrospectively analyzed.
Zhonghua Xin Xue Guan Bing Za Zhi
January 2025
Department of Pharmacy, the First Affiliated Hospital of Nanchang University, Nanchang330006, China.
J Appl Clin Med Phys
January 2025
Medical Physics Section, OHS Department, Hamad Medical Corporation, Doha, Qatar.
Purpose: To evaluate image quality (IQ) of for-processing (raw) and for-presentation (clinical) radiography images, under different exposure conditions and digital image post-processing algorithms, using a phantom that enables multiple detection tasks.
Methods: A modified version of the radiography phantom described in the IAEA Human Health Series No. 39 publication was constructed, incorporating six additional Aluminum (Al) targets of thicknesses both smaller and larger than the standard one.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!