Molecular dynamics simulations of NMR relaxation and diffusion of bulk hydrocarbons and water.

J Magn Reson

Rice University, Department of Chemical and Biomolecular Engineering, 6100 Main St., Houston, TX 77005, USA.

Published: April 2017

Molecular dynamics (MD) simulations are used to investigate H nuclear magnetic resonance (NMR) relaxation and diffusion of bulk n-CH to n-CH hydrocarbons and bulk water. The MD simulations of the H NMR relaxation times T in the fast motion regime where T=T agree with measured (de-oxygenated) T data at ambient conditions, without any adjustable parameters in the interpretation of the simulation data. Likewise, the translational diffusion D coefficients calculated using simulation configurations agree with measured diffusion data at ambient conditions. The agreement between the predicted and experimentally measured NMR relaxation times and diffusion coefficient also validate the forcefields used in the simulation. The molecular simulations naturally separate intramolecular from intermolecular dipole-dipole interactions helping bring new insight into the two NMR relaxation mechanisms as a function of molecular chain-length (i.e. carbon number). Comparison of the MD simulation results of the two relaxation mechanisms with traditional hard-sphere models used in interpreting NMR data reveals important limitations in the latter. With increasing chain length, there is substantial deviation in the molecular size inferred on the basis of the radius of gyration from simulation and the fitted hard-sphere radii required to rationalize the relaxation times. This deviation is characteristic of the local nature of the NMR measurement, one that is well-captured by molecular simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2017.02.001DOI Listing

Publication Analysis

Top Keywords

nmr relaxation
20
relaxation times
12
molecular dynamics
8
dynamics simulations
8
simulations nmr
8
relaxation diffusion
8
diffusion bulk
8
agree measured
8
data ambient
8
ambient conditions
8

Similar Publications

Magnetic resonance imaging (MRI) is frequently used to monitor disease progression in multiple sclerosis (MS). This study aims to systematically evaluate the correlation between MRI measures and histopathological changes, including demyelination, axonal loss, and gliosis, in the central nervous system of MS patients. We systematically reviewed post-mortem histological studies evaluating myelin density, axonal loss, and gliosis using quantitative imaging in MS.

View Article and Find Full Text PDF

Molecular miscibility of ASD blend components: an evaluation of (the added value of) solid state NMR spectroscopy and relaxometry.

J Pharm Sci

January 2025

Drug Delivery and Disposition, KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Campus Gasthuisberg ON2, Herestraat 49 b921, 3000 Leuven, Belgium. Electronic address:

In order to evaluate the stability of an amorphous solid dispersion (ASD) it is crucial to be able to accurately determine whether the ASD components are homogeneously mixed or not. Several solid-state analysis techniques are at the disposal of the formulation scientist, such as for example modulated differential scanning calorimetry (mDSC) and solid-state nuclear magnetic resonance spectroscopy (ssNMR). ssNMR is a robust, versatile, and accurate analysis technique with a large number of application possibilities.

View Article and Find Full Text PDF

Nuclear Magnetic Resonance Study of Monoclonal Antibodies Near an Oil-Water Interface.

J Pharm Sci

January 2025

Department of Chemical and Biomedical Engineering, FAMU-FSU College of Engineering, Tallahassee, FL, USA, 32310; Center for Interdisciplinary Magnetic Resonance, National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA, 32310. Electronic address:

Monoclonal antibodies (mAb) represent an important class of biologic therapeutics that can treat a variety of diseases including cancer, autoimmune disorders or respiratory conditions (e.g. COVID-19).

View Article and Find Full Text PDF

Tendon disease ranks among the leading reasons patients consult their general practitioners, comprising approximately one-third of musculoskeletal appointments. Magnetic resonance imaging (MRI) is regarded as the gold standard for assessing tendons. Due to their short transverse relaxation time (T2), Tendons show up as a signal void in conventional MRI scans, which employ sequences with echo times (TEs) around several milliseconds.

View Article and Find Full Text PDF

We investigated the extracellular and intracellular digestion of bivalves employing magnetic resonance imaging (MRI). Ruditapes philippinarum clams and Mytilus galloprovincialis mussels were incubated in seawater containing a contrast reagent (GdDTPA) at 20°C. The digestive systems, from the esophagus to the rectum, were visualized at a high signal intensity by the T1-weighted MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!