Bloodless reperfusion with the oxygen carrier HBOC-201 in acute myocardial infarction: a novel platform for cardioprotective probes delivery.

Basic Res Cardiol

Myocardial Pathophysiology Area, Translational Laboratory for Cardiovascular Imaging and Therapy, Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC), Melchor Fernández Almagro, 3, 28029, Madrid, Spain.

Published: March 2017

Reperfusion, despite being required for myocardial salvage, is associated with additional injury. We hypothesize that infarct size (IS) will be reduced by a period of bloodless reperfusion with hemoglobin-based oxygen carriers (HBOC) before blood-flow restoration. In the pig model, we first characterized the impact of intracoronary perfusion with a fixed volume (600 ml) of a pre-oxygenated acellular HBOC, HBOC-201, on the healthy myocardium. HBOC-201 was administered through the lumen of the angioplasty balloon (i.e., distal to the occlusion site) immediately after onset of coronary occlusion at 1, 0.7, 0.4, or 0.2 ml/kg/min for 12, 17, 30, and 60 min, respectively, followed by blood-flow restoration. Outcome measures were systemic hemodynamics and LV performance assessed by the state-of-the-art cardiac magnetic resonance (CMR) imaging. The best performing HBOC-201 perfusion strategies were then tested for their impact on LV performance during myocardial infarction, in pigs subjected to 45 min mid-left anterior descending (LAD) coronary occlusion. At the end of the ischemia duration, pigs were randomized to regular reperfusion (blood-only reperfusion) vs. bloodless reperfusion (perfusion with pre-oxygenated HBOC-201 distal to the occlusion site), followed by blood-flow restoration. Hemodynamics and CMR-measured LV performance were assessed at 7- and 45-day follow-up. In modifications of the HBOC-201 procedure, glucose and insulin were included to support cardiac metabolism. A total of 66 pigs were included in this study. Twenty healthy pigs (5 per infusion protocol) were used in the study of healthy myocardium. Intracoronary administration of HBOC-201 (600 ml) at varying rates, including a flow of 0.4 ml/kg/min (corresponding to a maximum perfusion time of 30 min), did not damage the healthy myocardium. Slower perfusion (longer infusion time) was associated with permanent LV dysfunction and myocardial necrosis. A total of 46 pigs underwent MI induction. Compared with regular reperfusion, bloodless reperfusion with pre-oxygenated HBOC-201 alone increased IS. This effect was reversed by enrichment of pre-oxygenated HBOC-201 solution with glucose and insulin, resulting in no increase in IS or worsening of long-term ventricular function despite further delaying restoration of blood flow in the LAD. Bloodless reperfusion with a pre-oxygenated HBOC-201 solution supplemented with glucose and insulin is feasible and safe, but did not reduce infarct size. This strategy could be, however, used to deliver agents to the myocardium to treat or prevent ischemia/reperfusion injury before blood-flow restoration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00395-017-0605-6DOI Listing

Publication Analysis

Top Keywords

bloodless reperfusion
20
blood-flow restoration
16
pre-oxygenated hboc-201
16
healthy myocardium
12
glucose insulin
12
hboc-201
10
myocardial infarction
8
reperfusion
8
infarct size
8
distal occlusion
8

Similar Publications

Objective: Noncompressible torso hemorrhage is a high-mortality injury. We previously reported improved outcomes with a retrievable rescue stent graft to temporize aortic hemorrhage in a porcine model while maintaining distal perfusion. A limitation was that the original cylindrical stent graft design prohibited simultaneous vascular repair, given the concern for suture ensnarement of the temporary stent.

View Article and Find Full Text PDF

Background: This study aims to compare the use of one-per-mil tumescent solution (a mixture of epinephrine and 0.2% lidocaine in a ratio of 1:1,000,000 in normal saline solution) and tourniquet to create clear operative fields and to evaluate the functional outcomes after post burn hand contracture surgery.

Methods: The subjects of this randomized controlled trial were divided into one-permil tumescent technique and tourniquet group for a similar surgical procedure.

View Article and Find Full Text PDF

During tourniquet application, blood flow is restricted to a limb to stop excessive limb hemorrhage in a trauma setting and to create a bloodless operating field in the surgical setting. During tourniquet-related ischemia, aerobic respiration stops, and ATP is depleted, and during subsequent reperfusion, there is an increase in reactive oxygen species (ROS) production and other endogenous substances, which leads to acute ischemia-reperfusion (IR) injuries, including tissue necrosis and skeletal muscle contractile dysfunction. Hyperbaric oxygen (HBO) therapy can increase the arterial oxygen tension in the tissues of patients with general hypoxia/anoxia, including carbon monoxide poisoning, circulatory arrest, and cerebral and myocardial ischemia.

View Article and Find Full Text PDF

A comparison of acute mouse hindlimb injuries between tourniquet- and femoral artery ligation-induced ischemia-reperfusion.

Injury

November 2021

Department of Emergency Medicine, University of Nebraska Medical Center, Omaha, NE 68198-5850, USA; Department of Cellular and Integrative Physiology, University of Nebraska Medical Center, Omaha, NE, USA. Electronic address:

The tourniquet or femoral artery ligation is widely used to stop extremity hemorrhage or create a bloodless operating field in the combat scenario and civilian setting. However, these procedures with subsequent reperfusion also induce ischemia-reperfusion (IR) injuries. To fully evaluate animal models of limb IR injuries, we compared tourniquet- and femoral artery ligation-induced IR injuries in the hindlimb of mice.

View Article and Find Full Text PDF

Incidence and factors influencing tourniquet pain.

Chin J Traumatol

September 2021

Department of Orthopaedics, Kasturba Medical College, Mangalore, Manipal Academy of Higher Education, Manipal, India.

Purpose: The use of tourniquet in orthopedic surgery facilitates operation by establishing a bloodless surgical field. However, many complications following the use of tourniquets have been reported. Tourniquet pain is the most common complication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!