Collapsed cone dose calculations for heterogeneous tissues in brachytherapy using primary and scatter separation source data.

Comput Methods Programs Biomed

Radiation Physics, Department of Medical and Health Sciences (IMH), Faculty of Health Sciences, Linköping University, SE-581 85 Linköping, Sweden; Department of Medical Physics, Section for Radiotherapy Physics and Engineering, Karolinska University Hospital, SE-171 76 Stockholm, Sweden. Electronic address:

Published: February 2017

Background And Objective: Brachytherapy is a form of radiation therapy using sealed radiation sources inserted within or in the vicinity of the tumor of, e.g., gynecological, prostate or head- and neck cancers. Accurate dose calculation is a crucial part of the treatment planning. Several reviews have called for clinical software with model-based algorithms that better take into account the effects of patient individual distribution of tissues, source-channel and shielding attenuation than the commonly employed TG-43 formalism which simply map homogeneous water dose distributions onto the patient. In this paper we give a comprehensive and thorough derivation of such an algorithm based on collapsed cone point-kernel superposition, and describe details of its implementation into a commercial treatment planning system for clinical use.

Methods: A brachytherapy version of the collapsed-cone algorithm using analytical raytraces of the primary photon radiation followed by successive scattering dose calculation for once- and multiply scattered photons is described in detail, including derivation of the corresponding set of recursive equations for energy transport along cone axes/transport lines and the coupling to clinical source modeling. Specific implementation issues for setting up of the calculation grid, handling of intravoxel gradients and voxels partly containing non-patient applicator material are given.

Results: Sample runs for two clinical cases are shown, one being a gynecological application with a tungsten-shielded applicator and one a breast implant. These two cases demonstrate the impact of improved dose calculation versus TG-43 formalism.

Conclusions: Use of model-based dose calculation algorithms for brachytherapy taking the three-dimensional treatment geometry into account increases the dosimetric accuracy in planning and follow up of treatments. The comprehensive description and derivations provided gives a rigid background for further clinical, educational and research applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2016.10.022DOI Listing

Publication Analysis

Top Keywords

dose calculation
16
collapsed cone
8
treatment planning
8
dose
6
calculation
5
clinical
5
cone dose
4
dose calculations
4
calculations heterogeneous
4
heterogeneous tissues
4

Similar Publications

Association of pan-immune-inflammatory value with metabolic dysfunction-associated steatotic liver disease: findings from NHANES 2017-2020.

BMC Gastroenterol

January 2025

Department of Gastroenterology and Hepatology, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, No. 55 Zhenhai Road, Xiamen, 361003, China.

Background: Metabolic dysfunction-associated steatotic liver disease (MASLD) has become the most common chronic liver disease worldwide. The pan-immune-inflammation value (PIV) has been proposed as a biomarker for assessing immune status and inflammation. There is currently no evidence regarding the effect of PIV on the risk of MASLD.

View Article and Find Full Text PDF

Background: Patients on a kidney transplant waiting list with antibodies against more than 80% of a panel reactive antibody (PRA) are difficult to transplant, even with national or regional programs. Desensitization treatment with high-dose intravenous immunoglobulin and rituximab could be offered to patients with a long waiting time for a cadaveric donor to improve their odds of finding a kidney.

Methods: This was a retrospective, single-center study including all hyperimmunized patients on the waiting list for a cadaveric kidney donor who received a desensitization treatment between 2010 and 2020.

View Article and Find Full Text PDF

Objective: To evaluate the added value of dynamic contrast-enhanced ultrasound (DCE-US) analysis in pre-operative differential diagnosis of small (≤20 mm) solid pancreatic lesions (SPLs).

Methods: In this retrospective study, patients with biopsy or surgerical resection and histopathologically confirmed small (≤20 mm) SPLs were included. One wk before biopsy/surgery, pre-operative B-mode ultrasound and contrast-enhanced ultrasound were performed.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials.

Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.

View Article and Find Full Text PDF

The tumorigenic dose 50 (TD) is a widely used measure of carcinogenic potency which has historically been used to determine acceptable intake limits for carcinogenic compounds. Although broadly used, the TD model was not designed to account for important biological factors such as DNA repair and cell compensatory mechanisms, changes in absorption, etc., leading to the development of benchmark dose (BMD) approaches, which use more flexible dose-response models that are better able to account for these processes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!