A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of amplicon-based NGS data from neurological disease gene panels: a new method for allele drop-out management. | LitMetric

Background: Amplicon-based targeted resequencing is a commonly adopted solution for next-generation sequencing applications focused on specific genomic regions. The reliability of such approaches rests on the high specificity and deep coverage, although sequencing artifacts attributable to PCR-like amplification can be encountered. Between these artifacts, allele drop-out, which is the preferential amplification of one allele, causes an artificial increase in homozygosity when heterozygous mutations fall on a primer pairing region. Here, a procedure to manage such artifacts, based on a pipeline composed of two steps of alignment and variant calling, is proposed. This methodology has been compared to the Illumina Custom Amplicon workflow, available on Illumina MiSeq, on the analysis of data obtained with four newly designed TruSeq Custom Amplicon gene panels.

Results: Four gene panels, specific for Parkinson disease, for Intracerebral Hemorrhage Diseases (COL4A1 and COL4A2 genes) and for Familial Hemiplegic Migraine (CACNA1A and ATP1A2 genes) were designed. A total of 119 samples were re-sequenced with Illumina MiSeq sequencer and panel characterization in terms of coverage, number of variants found and allele drop-out potential impact has been carried out. Results show that 14 % of identified variants is potentially affected by allele drop-out artifacts and that both the Custom Amplicon workflow and the procedure proposed here could correctly identify them. Furthermore, a more complex configuration in presence of two mutations was simulated in silico. In this configuration, our proposed methodology outperforms Custom Amplicon workflow, being able to correctly identify two mutations in all the studied configurations.

Conclusions: Allele drop-out plays a crucial role in amplicon-based targeted re-sequencing and specific procedures in data analysis of amplicon data should be adopted. Although a consensus has been established in the elimination of primer sequences from aligned data (e.g., via primer sequence trimming or soft clipping), more complex configurations need to be managed in order to increase the retrieved information from available data. Our method shows how to manage one of these complex configurations, when two mutations occur.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5123238PMC
http://dx.doi.org/10.1186/s12859-016-1189-0DOI Listing

Publication Analysis

Top Keywords

allele drop-out
20
custom amplicon
16
amplicon workflow
12
gene panels
8
amplicon-based targeted
8
proposed methodology
8
illumina miseq
8
variants allele
8
correctly identify
8
complex configurations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!