Determination of insertion depth of flexible laryngeal mask airway in pediatric population-A prospective observational study.

J Clin Anesth

Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, #101 Daehak-ro, Jongno-gu, Seoul 110-744, Republic of Korea. Electronic address:

Published: February 2017

Study Objective: The purpose of this study was to determine the ideal insertion depth of the flexible laryngeal mask airway (FLMA) by elucidating the relationships between insertion depth and patient's age, body weight, height, and other parameters. We also evaluated an insertion technique that uses the change in intracuff pressure for proper positioning of the FLMA in cases where it is difficult to sense resistance during FLMA insertion.

Design: This study was a prospective observational study.

Setting: Participants were recruited from the Seoul National University Children's Hospital.

Patients: We enrolled 154 children aged ≤15 years with an American Society of Anesthesiologists physical status of I or II who were scheduled for ophthalmic surgery of <2 hours duration under general anesthesia.

Interventions: After induction of general anesthesia, FLMA insertion was guided by the change in intracuff pressure, measured using a manometer. The FLMA position was assessed using a fiberoptic bronchoscope.

Measurements: The FLMA insertion depth was measured at the end of each surgical procedure. A multiple linear regression model was then created using age, height, weight, nasal-tragus length, and sternal length.

Main Results: The FLMA was successfully inserted in the first attempt in 134 patients using continuous monitoring of intracuff pressure. Using multiple linear regression analysis and the Durbin-Watson test, we found that insertion depth was best predicted by height and weight (r=0.777), and the resulting formula was as follows: insertion depth of FLMA (cm)=7.0+0.04×height (cm)+0.05 ×weight (kg).

Conclusions: The FLMA insertion depth can be calculated using height and weight. Continuous monitoring of intracuff pressure during FLMA insertion is a useful alternative insertion method in cases where resistance is difficult to sense.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jclinane.2016.10.012DOI Listing

Publication Analysis

Top Keywords

insertion depth
12
depth flexible
8
flexible laryngeal
8
laryngeal mask
8
mask airway
8
prospective observational
8
determination insertion
4
airway pediatric
4
pediatric population-a
4
population-a prospective
4

Similar Publications

Organisms have the capacity to detect day-night fluctuations through oscillators regulated by circadian clock genes, which are crucial for regulating various biological processes. Numerous studies have demonstrated a marked association between these genes and various growth traits of sheep. This study identified polymorphisms at 23 potential loci within five clock genes in four Chinese sheep breeds.

View Article and Find Full Text PDF

Introduction: Straw phonation therapy, a form of semi-occluded vocal tract (SOVT) exercise, is commonly used to help treat various voice disorders. Although straw phonation therapy has been studied extensively for decades, the impact of straw depth on vocal function remains unexplored. This study aims to quantify the effects of various straw vocal tract insertion depths (VTID) into the vocal tract on common aerodynamic parameters such as phonation threshold pressure (PTP), phonation threshold flow (PTF), and phonation threshold power (PTW) in an ex vivo canine model.

View Article and Find Full Text PDF

Purpose: To investigate the feasibility of a robotic system with artificial intelligence-based lesion detection and path planning for CT-guided biopsy, compared to the conventional freehand technique.

Materials And Methods: Eight nodules within an abdominal phantom, incorporating the simulated vertebrae and ribs, were designated as targets. A robotic system was used for lesion detection, trajectory generation, and needle-holder positioning.

View Article and Find Full Text PDF

Pile driving for offshore wind turbines typically generates high sound levels in the water column. Bubble curtains are frequently employed to protect marine fauna. This study aims to investigate the effect of a bubble curtain on the generated sound wave field.

View Article and Find Full Text PDF

The GacS/GacA two-component system strongly regulates antimicrobial competition mechanisms of MFE01 strain.

J Bacteriol

January 2025

Laboratoire de Communication Bactérienne et Stratégies Anti-infectieuses (CBSA UR4312, formerly LMSM EA4312), Univ Rouen Normandie, Université Caen Normandie, Normandie Univ, Rouen, France.

Unlabelled: MFE01 is an environmental bacterium characterized by an hyperactive type 6 secretion system (T6SS) and a strong emission of volatile organic compounds (VOCs). In a previous study, a transposition mutant, 3H5, exhibited an inactive T6SS and altered VOC emission. In 3H5, the interruption of gene by the transposon was insufficient to explain these phenotypes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!