A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasensitive detection of serum hepatitis B virus by coupling ultrafiltration DNA extraction with real-time PCR. | LitMetric

Background: A simple and reliable DNA extraction of hepatitis B virus (HBV) is critical in developing an ultrasensitive detection method for HBV infection. Current commercially available serum Hepatitis B Virus (HBV) DNA extraction methods are time-consuming, expensive and/or require specialized equipment, which hinders wide adoption of clinical laboratories. This study offers a report on an ultrasensitive HBV DNA detection method by coupling serum HBV DNA extraction by ultrafiltration (UF) with real-time PCR (qPCR) detection.

Methods: Serum proteins were precipitated by phenol to release HBV DNA in the supernatant which was then transferred to the UF devices. The resultant DNA concentrate was eluted and released into qPCR pre-mixture. The UF-qPCR assay performance, including recovery rate, linearity, detection sensitivity, precision and diagnostic accuracy that compared to the CAP-CTM V2.0 assay by analyzing batched low viral load clinical samples was evaluated.

Results: The recovery rate of the UF-based HBV DNA extraction method was above 80%. The assay linearity was demonstrated with a slope of 0.95 and R2 values of 0.99. Limit-of-detection (LOD) of the UF-qPCR assay was determined to be 12.1IU/ml. The coefficient of variation (CV) of HBV quantitation for high, low and limit titer samples was 2.28%, 5.77% and 25.59%, respectively. Accuracy of the UF-qPCR assay was confirmed with the reference panel, and there was a strong correlation between these two methods (R2 = 0.55, p < 0.01).

Conclusions: The UF-qPCR assay is reliable, highly sensitive, affordable and time-saving, and the method can be used for ultrasensitive detection of serum HBV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5300171PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0170290PLOS

Publication Analysis

Top Keywords

dna extraction
20
hbv dna
20
uf-qpcr assay
16
ultrasensitive detection
12
hepatitis virus
12
hbv
9
detection serum
8
serum hepatitis
8
dna
8
real-time pcr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!