Background: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4-6-mm tapered and 6-mm straight forearm loop arteriovenous grafts.

Methods: A total of 103 patients receiving forearm loop arteriovenous grafts between March 2005 and March 2015 were retrospectively analyzed and separated into 2 groups (group A, 4- to 6-mm tapered grafts, n=78; group B, 6-mm straight grafts, n=25). In each group, complications and patency rates after surgery were assessed.

Results: Clinical characteristics and laboratory results, except for cerebrovascular disease history (group A, 7.7%; group B, 28.0%; p=0.014), were similar between the groups. No significant differences were found for individual complications. Kaplan-Meier survival analysis revealed no significant differences in 1-year, 3-year, and 5-year patency rates between groups (61.8%, 44.9%, and 38.5% vs. 62.7%, 41.1%, and 35.3%, respectively).

Conclusion: We found no significant differences in complication and patency rates between the tapered and straight graft groups. If there are no differences in complication and patency between the two graft types, tapered grafts may be a valuable option for AVF formation in light of their other advantages.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5295480PMC
http://dx.doi.org/10.5090/kjtcs.2017.50.1.30DOI Listing

Publication Analysis

Top Keywords

forearm loop
12
loop arteriovenous
12
tapered grafts
12
patency rates
12
arteriovenous fistula
8
avf formation
8
6-mm straight
8
group 6-mm
8
groups differences
8
differences complication
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!