A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of an automatic reference region extraction for the quantification of [F]DPA-714 in dynamic brain PET studies. | LitMetric

Validation of an automatic reference region extraction for the quantification of [F]DPA-714 in dynamic brain PET studies.

J Cereb Blood Flow Metab

4 Commissariat à l'Energie Atomique et aux Energies Alternatives (CEA), Département de Recherche Fondamentale (DRF), Institut d'Imagerie Biomédicale (I2BM), Service Hospitalier Frédéric Joliot, Orsay, France.

Published: February 2018

There is a great need for a non-invasive methodology enabling the quantification of translocator protein overexpression in PET clinical imaging. [F]DPA-714 has emerged as a promising translocator protein radiotracer as it is fluorinated, highly specific and returned reliable quantification using arterial input function. Cerebellum gray matter was proposed as reference region for simplified quantification; however, this method cannot be used when inflammation involves cerebellum. Here we adapted and validated a supervised clustering (supervised clustering algorithm (SCA)) for [F]DPA-714 analysis. Fourteen healthy subjects genotyped for translocator protein underwent an [F]DPA-714 PET, including 10 with metabolite-corrected arterial input function and three for a test-retest assessment. Two-tissue compartmental modelling provided [Formula: see text] estimates that were compared to either [Formula: see text] or [Formula: see text] generated by Logan analysis (using supervised clustering algorithm extracted reference region or cerebellum gray matter). The supervised clustering algorithm successfully extracted a pseudo-reference region with similar reliability using classes that were defined using either all subjects, or separated into HAB and MAB subjects. [Formula: see text], [Formula: see text] and [Formula: see text] were highly correlated (ICC of 0.91 ± 0.05) but [Formula: see text] were ∼26% higher and less variable than [Formula: see text]. Reproducibility was good with 5% variability in the test-retest study. The clustering technique for [F]DPA-714 provides a simple, robust and reproducible technique that can be used for all neurological diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5951011PMC
http://dx.doi.org/10.1177/0271678X17692599DOI Listing

Publication Analysis

Top Keywords

[formula text]
32
supervised clustering
16
reference region
12
translocator protein
12
clustering algorithm
12
text] [formula
12
arterial input
8
input function
8
cerebellum gray
8
gray matter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!