Purpose: The aim of the present study was to systematically evaluate the marginal bone loss (MBL), success, and survival of zirconia (Zi) implants and compare them with the widely studied titanium (Ti) implants.

Materials And Methods: An electronic and manual literature search of several databases was performed by two independent reviewers for articles up to July 2015 that reported the use of Zi implants and survival, success, and MBL with at least 12 months' follow-up. In addition, random effects meta-analyses of selected studies were applied to analyze the weighted mean difference of survival, success, and MBL between groups. Meta-regression analysis was conducted to investigate any potential influence of confounding factors.

Results: Twenty-one articles were included, analyzing a total of 1,948 Zi implants with a survival rate of 91.5% and a success rate of 91.6% for 1,250 Zi implants. In addition, three studies were included in the quantitative synthesis and were meta-analyzed for the comparison of survival between Zi and Ti implants, with Zi implants having an 89% greater risk of failure compared with Ti implants (OR = 1.89). There were no statistically significant differences (P = .968) in the success of Zi and Ti implants (odds ratio [OR] = 1.02; 95% confidence interval [CI], 0.47-2.20). MBL (± SD) for Zi implants was 0.89 ± 0.18 mm, which was greater than the MBL for Ti implants (mean difference = 0.14 mm). Also, survival of Zi implants (91.5%) was significantly lower than that of Ti implants (OR = 1.89). Metaregression analysis revealed a similar survival rate for one-piece versus two-piece implants. Similarly, no significant differences were found between immediate and delayed loading.

Conclusions: The survival rate of Zi implants was significantly lower than that for the commonly used Ti implants. However, for certain clinical conditions, such as a thin tissue biotype or in the highly esthetic anterior area, Zi implants may offer some benefit when compared with Ti implants.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.5223DOI Listing

Publication Analysis

Top Keywords

implants
17
survival rate
12
zirconia implants
8
survival
8
implants survival
8
survival success
8
success mbl
8
survival implants
8
compared implants
8
implants 189
8

Similar Publications

Background: The occurrence of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) might be associated with the proximal femoral morphology and the pelvis. PFFs in short stem THA are associated with an increased Canal Flare Index. PFFs in straight stem THA show a decreased Canal Flare Index.

View Article and Find Full Text PDF

Background: He's team have recently developed a new Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system, which is capable of accounting for the variability in coronary anatomy, and risk-stratifying patients with coronary artery disease. Preliminary studies have demonstrated its superiority over the the Synergy between percutaneous coronary intervention with Taxus and Cardiac Surgery (SYNTAX) score with respect to outcome predictions for acute myocardial infarction (AMI) patients. However, there are fewer studies on the prognostic in chronic coronary artery disease(CAD).

View Article and Find Full Text PDF

Bioelectronic osteosynthesis plate to monitor the fracture bone healing using electric capacitive variations.

J Orthop Surg Res

January 2025

Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, Aveiro, 3810-193, Portugal.

Background: Bone fractures represent a global public health issue. Over the past few decades, a sustained increase in the number of incidents and prevalent cases have been reported, as well as in the years lived with disability. Current monitoring techniques predominantly rely on imaging methods, which can result in subjective assessments, and expose patients to unnecessary cumulative doses of radiation.

View Article and Find Full Text PDF

Anti-inflammatory coupled anti-angiogenic airway stent effectively suppresses tracheal in-stents restenosis.

J Nanobiotechnology

January 2025

Department of Interventional Radiology, Key Laboratory of Interventional Radiology of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450001, China.

Excessive vascularization during tracheal in-stent restenosis (TISR) is a significant but frequently overlooked issue. We developed an anti-inflammatory coupled anti-angiogenic airway stent (PAGL) incorporating anlotinib hydrochloride and silver nanoparticles using advanced electrospinning technology. PAGL exhibited hydrophobic surface properties, exceptional mechanical strength, and appropriate drug-release kinetics.

View Article and Find Full Text PDF

Background: Treatment of ankle osteoarthritis by total ankle replacement (TAR) is increasing worldwide. The aim of the study was to present the overall temporal trends of TAR throughout 22 years (2001-2022) in Italy, analyzing the distributions of hospitals by volume of activity and patients by age and sex, drawing on the National Hospital Discharge Record database. Furthermore, as a secondary aim, we compared these trends with those of ankle fusions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!