A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review. | LitMetric

Aim: Haemolysis has a major impact on patient safety as the need for a replacement specimen increases the risk of injury and infection, delays test results and extends the duration of hospital stays. Consistency of haemolysis detection and reporting can facilitate the generation of benchmark data used to develop quality practices to monitor and reduce this leading cause of pre-analytical laboratory error. This review aims to investigate current methods of haemolysis detection and reporting.

Method: Due to known heterogeneity and immaturity of the research field, a scoping search was conducted using PUBMED, Embase, Medline and CINAHL. Articles published between 2000 and 2014 that reported haemolysis rates in specimens from the general population were included.

Results: Of the 50 studies that met the inclusion criteria, 20 detected haemolysis using the Haemolysis Index (HI), 19 by visual inspection and 13 by undefined methods. There was large intra-study variation in the plasma free haemoglobin level used to establish haemolysis (HI: mean±SD 846±795 mg/L, range 150-3000 mg/L; Visual: 850±436 mg/L, 500-3000 mg/L). Sixteen studies reported the analyte of interest, with only three studies reporting a haemoglobin level at which the specimen would be rejected.

Conclusion: Despite haemolysis being a frequent and costly problem with a negative impact on patient care, there is poor consistency in haemolysis detection and reporting between studies. Improved consistency would facilitate the generation of benchmark data used to create quality practices to monitor and reduce this leading cause of pre-analytical laboratory error.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5242478PMC

Publication Analysis

Top Keywords

haemolysis detection
16
detection reporting
12
haemolysis
10
current methods
8
methods haemolysis
8
patient safety
8
impact patient
8
consistency haemolysis
8
facilitate generation
8
generation benchmark
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!