Background: We previously reported the clinical feasibility and positive impact on image characteristics of a data-driven cardiac respiratory motion (RM) correction method (REGAT) applicable to CZT SPECT myocardial perfusion imaging (MPI). Here, we evaluate its impact on the extent and severity of myocardial perfusion defects (MPD).

Methods: We included 25 patients having a 1-day Tc-Tetrofosmin stress/rest MPI acquired with multi-pinhole CZT SPECT. Acquisitions were processed with REGAT to generate mean RM gated SPECT. These were summed either after (R-SPECT) or without realignment (NR-SPECT). We noted the maximal cardiac RM shift in the 3 axes of the left ventricle (LV). Both visual and semi-quantitative analyses of myocardial tracer uptake were realized. Studies were classified as having an impact on the extent/severity of MPD with REGAT if ≥1 segment presented a severity score changing by ≥1 level between NR-SPECT and R-SPECT. An impact on the extent of MPD was considered present if at least 1 segment shifted from normal (score = 0) to abnormal (score different from 0) or inversely.

Results: Cardiac RM was >10 mm in 55% of studies. With visual and semi-quantitative analyses, an impact on the extent/severity MPD was observed in 14% of all studies (7/49) and 60% of studies with cardiac RM >15 mm. An impact on the extent of MPD was observed in 5 of the 7 upper listed studies. All studies presenting an impact on MPD had RM in the anterior to inferior LV axis >10 mm.

Conclusions: A substantial number of MPI studies presented significant cardiac RM. Cardiac RM compensation showed a frequent impact on the extent/severity of MPD.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12350-017-0806-2DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
12
czt spect
12
impact extent
12
impact extent/severity
12
extent/severity mpd
12
impact
9
data-driven cardiac
8
cardiac respiratory
8
respiratory motion
8
motion correction
8

Similar Publications

Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.

View Article and Find Full Text PDF

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Nuclear Cardiology Surrogate Biomarkers in Clinical Trials.

J Nucl Med

January 2025

Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California;

Nuclear cardiology offers a diverse range of imaging tools that provide valuable insights into myocardial perfusion, inflammation, metabolism, neuroregulation, thrombosis, and microcalcification. These techniques are crucial not only for diagnosing and managing cardiovascular conditions but also for gaining pathophysiologic insights. Surrogate biomarkers in nuclear cardiology, represented by detectable imaging changes, correlate with disease processes or therapeutic responses and can serve as endpoints in clinical trials when they demonstrate a clear link with these processes.

View Article and Find Full Text PDF

Background: Non-response to cardiac resynchronization therapy (CRT) is an important issue in the treatment of heart failure with reduced ejection fraction (HFrEF) and non-left bundle branch block (LBBB). Electrocardiogram-gated myocardial perfusion single-photon emission computed tomography imaging (G-MPI SPECT) is typically used to assess left ventricular (LV) dyssynchrony. This study aimed to determine whether G-MPI parameters are associated with non-responsiveness to CRT.

View Article and Find Full Text PDF

Correlation between abnormal microvascular perfusion and quantitative flow ratio after primary PCI in patients with STEMI.

Int J Cardiol

December 2024

Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China; Cardiovascular Research Institute of Wuhan University, Wuhan, China; Hubei Key Laboratory of Cardiology, Wuhan, China. Electronic address:

Aims: Timely assessment of abnormal microvascular perfusion (MVP) may improve prognosis in patients with ST-segment elevation myocardial infarction (STEMI). This study aimed to determine the clinical implications of contrast-flow quantitative flow ratio (cQFR) in evaluating abnormal MVP and subsequent outcomes among STEMI patients after successful primary percutaneous coronary intervention (PPCI).

Methods: The study population consisted of 2 independent cohorts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!